ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Improved motion compensation in 3D-CT using respiratory-correlated segment reconstruction: Diagnostic and radiotherapy applications

https://repo.qst.go.jp/records/44816
https://repo.qst.go.jp/records/44816
6bb4b52d-e842-4882-a3c3-35de255f6beb
Item type 学術雑誌論文 / Journal Article(1)
公開日 2007-03-31
タイトル
タイトル Improved motion compensation in 3D-CT using respiratory-correlated segment reconstruction: Diagnostic and radiotherapy applications
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Mori, Shinichiro

× Mori, Shinichiro

WEKO 445070

Mori, Shinichiro

Search repository
Endo, Masahiro

× Endo, Masahiro

WEKO 445071

Endo, Masahiro

Search repository
Kohno, Ryosuke

× Kohno, Ryosuke

WEKO 445072

Kohno, Ryosuke

Search repository
Minohara, Shinichi

× Minohara, Shinichi

WEKO 445073

Minohara, Shinichi

Search repository
森 慎一郎

× 森 慎一郎

WEKO 445074

en 森 慎一郎

Search repository
遠藤 真広

× 遠藤 真広

WEKO 445075

en 遠藤 真広

Search repository
河野 良介

× 河野 良介

WEKO 445076

en 河野 良介

Search repository
蓑原 伸一

× 蓑原 伸一

WEKO 445077

en 蓑原 伸一

Search repository
抄録
内容記述タイプ Abstract
内容記述 Conventional respiratory-gated CT and four-dimentional CT(4DCT) are disadvantaged by their low temporal resolution, which results in the inclusion of anatomic motion-induced artefacts. These represent a significant source of error both in radiotherapy treatment planning for the thorax and upper abdomen and in diagnostic procedures. In particular, temporal resolution and image quality are vitally important to accurate diagnosis and the minimization of planning target volume margin due to respiratory motion. To improve both temporal resolution and signal-to-noise ratio (SNR), we developed a respiratory-correlated segment reconstruction method (RS) and adapted it to the Feldkamp-Davis-Kress algorithm (FDK) with a 256 multidetector row CT (256MDCT). The 256MDCT scans appromimately 100 mm in the craniocaudal direction with a 0.5 mm slice thickness in one rotation. Data acquisition for the RS-FDK relies on the assistance of a respiratory senssing system operating in cine scan mode (continuous axial scan with the table stationary). We evaluated the RS-FDK for volume accuracy and image noise in aphotom study with the 256MDCT and compared results with those for a full scan (FS-FDK), which is usually employed in conventional 4DCT and in half scan (HS-FDK). Results showed that the RS-FDK. In a subsequent animal study, we demonstrated a practical sorting process for projection subsequeent animal asudy, we demonstrated a practical sorting process for projection data which was unaffected by variations in respiratory period, and found that the RS-FDK gave the clearest visualization among the three algorithms of the margins of the liver and pulmonary vessels. In summary, the RS-FDK algorithm provides multi-phase images with highere temporal resolutin and better SNR. This method should prove useful when combined with new radiotherapeutic and diagnostic techniques.
書誌情報 British Journal of Radiology

巻 79, 号 945, p. 745-755, 発行日 2006-09
ISSN
収録物識別子タイプ ISSN
収録物識別子 0007-1285
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:11:01.076804
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3