  1. 原著論文

Improvement in banding artefacts in four-dimensional computed tomography for radiotherapy planning

https://repo.qst.go.jp/records/44787
https://repo.qst.go.jp/records/44787
6b3b647a-5170-4312-9ade-56dc8359dcf1
Item type 学術雑誌論文 / Journal Article(1)
公開日 2007-02-09
タイトル
タイトル Improvement in banding artefacts in four-dimensional computed tomography for radiotherapy planning
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Mori, Shinichiro

× Mori, Shinichiro

WEKO 444716

Mori, Shinichiro

Search repository
Endo, Masahiro

× Endo, Masahiro

WEKO 444717

Endo, Masahiro

Search repository
Asakura, Hiroshi

× Asakura, Hiroshi

WEKO 444718

Asakura, Hiroshi

Search repository
森 慎一郎

× 森 慎一郎

WEKO 444719

en 森 慎一郎

Search repository
遠藤 真広

× 遠藤 真広

WEKO 444720

en 遠藤 真広

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose: Respiratory-gated CT (RGCT) and four-dimensional CT (4DCT) scan techniques cover consecutive segments of the respiratory cycle. However, motion artifacts may occur in fast respiratory phases such as mid-inhalation and -exhalation. CT imaging involves the use of a number of x-ray tube positions for each couch position. We investigated the fundamental nature of motion artifacts using a constant-velocity moving phantom in motion in the CT plane or perpendicular to the CT plane, and in pigs to simulate a human model.
Methods and Materials: Artifacts and movement distance were evaluated in a moving phantom and artificially ventilated pigs with a 256-multi-detector row CT (256MDCT). The phantom moved in the CT plane or perpendicular to the CT plane with a constant velocity. Backprojection used variable initial Backprojection angles (IBAs).
Results: Phantom length for motion perpendicular to the CT plane was independent of IBA but was represented by phantom diameter plus the distance of movement per gantry rotation. In contrast, that for motion in the CT plane was dependent on IBA, as represented by phantom diameter plus the distance of movement per rotation for IBA perpendicular to the phantom movement direction, and phantom diameter plus half the distance of movement per gantry rotation for other IBAs. Results for volumetric CT images with different IBAs showed the presence of banding artifacts. Similar findings were seen in artificially ventilated pigs.
Conclusions: Motion artifacts are unavoidable in both conventional CT and 256MDCT. Banding artifacts will be improved if the same IBAs at each couch position are accounted for during image reconstruction. This improvement will be beneficial in respiratory gated and 4D radiation therapies.
書誌情報 Physics in Medicine and Biology

巻 51, 号 20, p. 5231-5244, 発行日 2006-10
ISSN
収録物識別子タイプ ISSN
収録物識別子 0031-9155
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:11:20.756294
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3