ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Cell labeling for magnetic resonance imaging with the T1 agent manganese chloride.

https://repo.qst.go.jp/records/44710
https://repo.qst.go.jp/records/44710
cf8b9f5b-481e-49e3-9bf6-f182d532cf5e
Item type 学術雑誌論文 / Journal Article(1)
公開日 2006-11-20
タイトル
タイトル Cell labeling for magnetic resonance imaging with the T1 agent manganese chloride.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Aoki, Ichio

× Aoki, Ichio

WEKO 443893

Aoki, Ichio

Search repository
et.al

× et.al

WEKO 443894

et.al

Search repository
青木 伊知男

× 青木 伊知男

WEKO 443895

en 青木 伊知男

Search repository
抄録
内容記述タイプ Abstract
内容記述 There is growing interest in using MRI to track cellular migration. To date, most work in this area has been performed using ultra-small particles of iron oxide. Immune cells are difficult to label with iron oxide particles. The ability of adoptively infused tumor specific T cells and N cells to traffic to the tumor microenvironment may be a critical determinant of their therapeutic efficacy.We tested the hypothesis that lymphocytes and B cells would label with MnCl2 to a level that would allow their detection by T1-weighted MRI. Significant signal enhancement was observed in human lymphocytes after a 1 h incubation with 0.05_1.0mM MnCl2. A flow cytometry-based evaluation using propidium iodide and Annexin V staining showed that lymphocytes did not undergo apoptosis or necrosis immediately after and 24 h following a 1 h incubation with up to 1.0mM MnCl2. Importantly, NK cells and cytotoxic T cells maintained their in vitro killing capacity after being incubated with up to 0.5mM MnCl2. This is the first report to describe the use of MnCl2 to label lymphocytes. Our data suggests MnCl2 might be an alternative to iron oxide cell labeling for MRI-based cell migrationstudies.
書誌情報 NMR in Biomedicine

巻 19, 号 1, p. 50-59, 発行日 2006
ISSN
収録物識別子タイプ ISSN
収録物識別子 0952-3480
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:12:15.616148
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3