Optimizing T2-weighted magnetic resonance sequences for surface coil microimaging of the eye with regard to lid, eyeball and head moving artifacts

https://repo.qst.go.jp/records/44620
https://repo.qst.go.jp/records/44620
882af8fd-f661-4442-9eb5-4e42989abcc7
Item type 学術雑誌論文 / Journal Article(1)
公開日 2006-09-25
タイトル
タイトル Optimizing T2-weighted magnetic resonance sequences for surface coil microimaging of the eye with regard to lid, eyeball and head moving artifacts
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Obata, Takayuki

× Obata, Takayuki

WEKO 443172

Obata, Takayuki

Search repository
Uemura, Koji

× Uemura, Koji

WEKO 443173

Uemura, Koji

Search repository
Nonaka, Hiroi

× Nonaka, Hiroi

WEKO 443174

Nonaka, Hiroi

Search repository
Tamura, Mitsuru

× Tamura, Mitsuru

WEKO 443175

Tamura, Mitsuru

Search repository
Tanada, Shuji

× Tanada, Shuji

WEKO 443176

Tanada, Shuji

Search repository
Ikehira, Hiroo

× Ikehira, Hiroo

WEKO 443177

Ikehira, Hiroo

Search repository
小畠 隆行

× 小畠 隆行

WEKO 443178

en 小畠 隆行

Search repository
上村 幸司

× 上村 幸司

WEKO 443179

en 上村 幸司

Search repository
野中 博意

× 野中 博意

WEKO 443180

en 野中 博意

Search repository
田村 充

× 田村 充

WEKO 443181

en 田村 充

Search repository
棚田 修二

× 棚田 修二

WEKO 443182

en 棚田 修二

Search repository
池平 博夫

× 池平 博夫

WEKO 443183

en 池平 博夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose: To acquire high-resolution magnetic resonance (MR) images, we developed a new blinking artifact reduced pulse (BARP) sequence with a surface coil specialized for microscopic imaging (47 mm in diameter).
Materials and Methods: To reduce eye movement, we ascertained that the subjects' eyes were kept open and fixated to the target in the 1.5-T MR gantry. To reduce motion artifacts from blinking, we inserted rest periods for blinking (1.5 s within every 5 s) during MR scanning (T2-weighted fast spin echo; repetition time, 5 s; echo time, 100 ms; echo train, 11; matrix, 256 x 128; field of view, 5 cm; 1-mm thickness x 30 slices). Three scans (100 s x 3) were performed for each normal subject, and they were added together after automatic adjustment for location to reduce quality loss caused by head motion.
Results: T2-weighted MR images were acquired with a high resolution and a high signal-to-noise ratio. Motion artifacts were reduced with BARP, as compared with those with random blinking. Intraocular structures such as the iris and ciliary muscles were clearly visualized. Because the whole eye can be covered with a 1-mm thickness by this method, three-dimensional maps can easily be generated from the obtained images.
Conclusion: The application of BARP with a surface coil of the human eye might become a useful and widely adopted procedure for MR microimaging.
書誌情報 Magnetic Resonance Imaging

巻 24, 号 1, p. 97-101, 発行日 2006
ISSN
収録物識別子タイプ ISSN
収録物識別子 0730-725X
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:13:18.952632
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3