ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Effects of image reconstruction algorithm on neurotransmission PET studies in humans: comparison between filtered backprojection and ordered subsets expectation maximization

https://repo.qst.go.jp/records/44515
https://repo.qst.go.jp/records/44515
8457d5b1-cf9e-4454-9a12-56c932e20a69
Item type 学術雑誌論文 / Journal Article(1)
公開日 2006-08-01
タイトル
タイトル Effects of image reconstruction algorithm on neurotransmission PET studies in humans: comparison between filtered backprojection and ordered subsets expectation maximization
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Morimoto, Takuya

× Morimoto, Takuya

WEKO 442328

Morimoto, Takuya

Search repository
Ito, Hiroshi

× Ito, Hiroshi

WEKO 442329

Ito, Hiroshi

Search repository
Takano, Akihiro

× Takano, Akihiro

WEKO 442330

Takano, Akihiro

Search repository
Ikoma, Youko

× Ikoma, Youko

WEKO 442331

Ikoma, Youko

Search repository
Seki, Chie

× Seki, Chie

WEKO 442332

Seki, Chie

Search repository
Okauchi, Takashi

× Okauchi, Takashi

WEKO 442333

Okauchi, Takashi

Search repository
Tanimoto, Katsuyuki

× Tanimoto, Katsuyuki

WEKO 442334

Tanimoto, Katsuyuki

Search repository
Ando, Akira

× Ando, Akira

WEKO 442335

Ando, Akira

Search repository
Shiraishi, Takahiro

× Shiraishi, Takahiro

WEKO 442336

Shiraishi, Takahiro

Search repository
Yamaya, Taiga

× Yamaya, Taiga

WEKO 442337

Yamaya, Taiga

Search repository
Suhara, Tetsuya

× Suhara, Tetsuya

WEKO 442338

Suhara, Tetsuya

Search repository
森本 卓哉

× 森本 卓哉

WEKO 442339

en 森本 卓哉

Search repository
伊藤 浩

× 伊藤 浩

WEKO 442340

en 伊藤 浩

Search repository
高野 晶寛

× 高野 晶寛

WEKO 442341

en 高野 晶寛

Search repository
生駒 洋子

× 生駒 洋子

WEKO 442342

en 生駒 洋子

Search repository
関 千江

× 関 千江

WEKO 442343

en 関 千江

Search repository
岡内 隆

× 岡内 隆

WEKO 442344

en 岡内 隆

Search repository
谷本 克之

× 谷本 克之

WEKO 442345

en 谷本 克之

Search repository
山谷 泰賀

× 山谷 泰賀

WEKO 442346

en 山谷 泰賀

Search repository
須原 哲也

× 須原 哲也

WEKO 442347

en 須原 哲也

Search repository
抄録
内容記述タイプ Abstract
内容記述 OBJECTIVES: Both reconstruction algorithms, filtered backprojection (FBP) and ordered subsets expectation maximization (OSEM), are widely used in clinical positron emission tomography (PET) studies. Image reconstruction for most neurotransmission PET scan data is performed by FBP, while image reconstruction for whole-body [18F]FDG scan data is usually performed by OSEM. Although several investigators have compared FBP and OSEM in terms of the quantification of regional radioactivity and physiological parameters calculated from PET data, only a few studies have compared the two reconstruction algorithms in PET studies that estimate neurotransmission, i.e., neuroreceptor and neurotransporter binding. In this study we compared mean regional radioactivity concentration in the late phase and binding potential (BP) between FBP and OSEM algorithms in neurotransmission PET studies for [11C]raclopride and [11C]DASB. METHODS: Dynamic PET scans with [11C]raclopride in 3-dimensional mode were performed on seven healthy subjects. Dynamic PET scans with [11C]DASB in 2-dimensional mode were performed on another seven subjects. OSEM images were post-filtered so that its transverse spatial resolution became similar to that of FBP with the same Hanning filter (Kernel FWHM 6 mm). In both PET studies we calculated the BP of [11C]raclopride and [11C]DASB by a reference tissue model for each ROI (region of interest). RESULTS: There was no significant difference in mean regional radioactivity concentration between FBP and OSEM for [11C]raclopride and [11C]DASB. Only +2.4 - +3.2%, but still a significant difference in BP of [11C]raclopride between FBP and OSEM was observed in the striatum. There was no significant difference in BP between FBP and OSEM in other than the striatum for [11C]raclopride and in all regions for [11C]DASB. In addition, there was no significant difference in root mean square error between FBP and OSEM when BP was calculated. CONCLUSIONS: The BP values were similar between FBP and OSEM algorithms with [11C]raclopride and [11C]DASB. This study indicates that OSEM can be used for human neurotransmission PET studies for calculating BP although OSEM was not necessarily superior to FBP in the present study.
書誌情報 Annals of Nuclear Medicine

巻 20, 号 3, p. 237-243, 発行日 2006-04
ISSN
収録物識別子タイプ ISSN
収録物識別子 0914-7187
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:14:33.870470
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3