ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Application of MLE method to range determination with induced beta+ activity in hadron therapy

https://repo.qst.go.jp/records/44504
https://repo.qst.go.jp/records/44504
3c61b21e-d74f-4c90-8ff4-4f0a73222cff
Item type 学術雑誌論文 / Journal Article(1)
公開日 2006-07-28
タイトル
タイトル Application of MLE method to range determination with induced beta+ activity in hadron therapy
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Inaniwa, Taku

× Inaniwa, Taku

WEKO 442220

Inaniwa, Taku

Search repository
Kohno, Toshiyuki

× Kohno, Toshiyuki

WEKO 442221

Kohno, Toshiyuki

Search repository
Tomitani, Takehiro

× Tomitani, Takehiro

WEKO 442222

Tomitani, Takehiro

Search repository
Kanazawa, Mitsutaka

× Kanazawa, Mitsutaka

WEKO 442223

Kanazawa, Mitsutaka

Search repository
Satou, Shinji

× Satou, Shinji

WEKO 442224

Satou, Shinji

Search repository
Urakabe, Eriko

× Urakabe, Eriko

WEKO 442225

Urakabe, Eriko

Search repository
Kanai, Tatsuaki

× Kanai, Tatsuaki

WEKO 442226

Kanai, Tatsuaki

Search repository
稲庭 拓

× 稲庭 拓

WEKO 442227

en 稲庭 拓

Search repository
河野 俊之

× 河野 俊之

WEKO 442228

en 河野 俊之

Search repository
富谷 武浩

× 富谷 武浩

WEKO 442229

en 富谷 武浩

Search repository
金澤 光隆

× 金澤 光隆

WEKO 442230

en 金澤 光隆

Search repository
佐藤 眞二

× 佐藤 眞二

WEKO 442231

en 佐藤 眞二

Search repository
金井 達明

× 金井 達明

WEKO 442232

en 金井 達明

Search repository
抄録
内容記述タイプ Abstract
内容記述 We proposed to apply the MLE method for determining the range of heavy ions and demonstrated the effectiveness of this method by experiments with 12C beams. We performed irradiation experiments with stable 12C ions of mono-energetic 290 MeV/u to a water, a polyethylene and a PMMA target. The theoretical ranges for 12C ions of 290 MeV/u in these targets are 160.5, 157.9 and 139.8 mm, respectively. The anihilation events from positron emitters generated by 12C ions were detected with a positron camera for 500 s just after the irradiation. To evaluate the range of 12C ions, the MLE method was applied to the annihilation gamma ray distribution. The
derived ranges for the three targets were 160.6, 158.9 and 140.4 mm, respectively. Therefore, we can conclude that the range of 12C ions was determined within an accuracy of 1.0mm for all targets.
書誌情報 Nuclear Instruments & Methods in Physics Research Section A

巻 562, 号 2, p. 1017-1019, 発行日 2006-06
ISSN
収録物識別子タイプ ISSN
収録物識別子 0168-9002
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:14:41.834607
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3