Uptakes and Images of 38K in Rabbit Heart, Kidney, and Brain

https://repo.qst.go.jp/records/44424
https://repo.qst.go.jp/records/44424
1f82ecd3-575e-4335-b8f7-18d3e3a9e460
Item type 学術雑誌論文 / Journal Article(1)
公開日 2006-07-06
タイトル
タイトル Uptakes and Images of 38K in Rabbit Heart, Kidney, and Brain
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yoshida, Katsuya

× Yoshida, Katsuya

WEKO 441454

Yoshida, Katsuya

Search repository
Tadokoro, Hiroyuki

× Tadokoro, Hiroyuki

WEKO 441455

Tadokoro, Hiroyuki

Search repository
Sato, Mikio

× Sato, Mikio

WEKO 441456

Sato, Mikio

Search repository
Suzuki, Kazutoshi

× Suzuki, Kazutoshi

WEKO 441457

Suzuki, Kazutoshi

Search repository
Masuda, Yoshiaki

× Masuda, Yoshiaki

WEKO 441458

Masuda, Yoshiaki

Search repository
Tanada, Shuji

× Tanada, Shuji

WEKO 441459

Tanada, Shuji

Search repository
et.al

× et.al

WEKO 441460

et.al

Search repository
吉田 勝哉

× 吉田 勝哉

WEKO 441461

en 吉田 勝哉

Search repository
田所 裕之

× 田所 裕之

WEKO 441462

en 田所 裕之

Search repository
佐藤 幹生

× 佐藤 幹生

WEKO 441463

en 佐藤 幹生

Search repository
鈴木 和年

× 鈴木 和年

WEKO 441464

en 鈴木 和年

Search repository
棚田 修二

× 棚田 修二

WEKO 441465

en 棚田 修二

Search repository
抄録
内容記述タイプ Abstract
内容記述 The purpose of this study was to evaluate the kinetics and image quality of positron-emitting 38K (half-life, 7.6 min) and high-resolution small-animal PET in the heart, kidney, and brain of rabbits. Methods: Studies were performed with 18 closed-chest anesthetized rabbits at baseline and during infusions of adenosine (0.2 mg/kg/min) and propranolol (0.5-1.0 mg/kg intravenously) using high-resolution small-animal PET. 38K was injected intravenously and dynamic PET imaging of the heart, kedney, or brain was performed for 3 min. Colored microspheres were injected into the left ventricle to measure organ blood flow. Arterial blood was withdrawn directly from the femoral artery, and, after the animals were killed, 38K activities in each organ were measured directly with a well counter. Uptake of 38K was calculated by dividing the 38K activities in each organ by the integral of the input function. THe extraction fraction of 38K was estimated by dividing the uptake of 38K in each organ by the organ blood flow, measured by microspheres. Results: The left ventricular myocardium and kidney were clearly visualized, but there was no visual 38K uptake in the brain. For the heart, kidney, and brain, respectively, average blood flow was 2.91 1.29, 5.49 0.71 and 0.57 0.11 mL/min/g, and the extraction fraction of 38K at baseline was 0.55 0.13, 0.48 0.13, and 0.022 0.004. The Renkin-Crone model fit the relation between myocardial extraction and flow under an wide range of myocardial blood flow (r=0.89). Conclusion: 38K is a suitable tracer for noninvasvely showing the potassium kinetics of hte heart, kidney, and brain by PET imaging.
書誌情報 Journal of Nuclear Medicine

巻 41, 号 4, p. 763-769, 発行日 2000-04
ISSN
収録物識別子タイプ ISSN
収録物識別子 0161-5505
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:15:37.463954
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3