  1. 原著論文

Physical evaluation of multidetector-row computed tomography (MDCT) scan methods and conditions for improvement of carbon beam distribution

https://repo.qst.go.jp/records/44394
https://repo.qst.go.jp/records/44394
cda21770-1ec6-4ef3-a733-4ad5235f672c
Item type 学術雑誌論文 / Journal Article(1)
公開日 2006-07-04
タイトル
タイトル Physical evaluation of multidetector-row computed tomography (MDCT) scan methods and conditions for improvement of carbon beam distribution
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Mori, Shinichiro

× Mori, Shinichiro

WEKO 441083

Mori, Shinichiro

Search repository
Kohno, Ryosuke

× Kohno, Ryosuke

WEKO 441084

Kohno, Ryosuke

Search repository
Nishio, Teiji

× Nishio, Teiji

WEKO 441085

Nishio, Teiji

Search repository
Mizuno, Hideyuki

× Mizuno, Hideyuki

WEKO 441086

Mizuno, Hideyuki

Search repository
Yamashita, Hiroyo

× Yamashita, Hiroyo

WEKO 441087

Yamashita, Hiroyo

Search repository
Asakura, Hiroshi

× Asakura, Hiroshi

WEKO 441088

Asakura, Hiroshi

Search repository
Endo, Masahiro

× Endo, Masahiro

WEKO 441089

Endo, Masahiro

Search repository
et.al

× et.al

WEKO 441090

et.al

Search repository
森 慎一郎

× 森 慎一郎

WEKO 441091

en 森 慎一郎

Search repository
河野 良介

× 河野 良介

WEKO 441092

en 河野 良介

Search repository
西尾 禎治

× 西尾 禎治

WEKO 441093

en 西尾 禎治

Search repository
水野 秀之

× 水野 秀之

WEKO 441094

en 水野 秀之

Search repository
山下 裕代

× 山下 裕代

WEKO 441095

en 山下 裕代

Search repository
遠藤 真広

× 遠藤 真広

WEKO 441096

en 遠藤 真広

Search repository
抄録
内容記述タイプ Abstract
内容記述 To reduce errors in the carbon beam distribution between the treatment planning system and the actual situation, we evaluated the geometrical accuracy, volume accuracy, water equivalent length (WEL), and treatment planning, and compared the evaluation results of axial and helical scan methods with various scan parameters. The results indicated that both scan methods show good geometrical accuracy for thin slice thickness, but for thick slice images it is easier to understand the phantom as a sphere from the helical as compared with the axial scan. Treatment planning with thin slice thickness provided accurate dose distribution for both scan methods, and the dose distribution on the treatment planning system was almost the same as that in the actual situation. Not all institutes, however, can obtain thin slice CT images, and some used thick-slice CT images in planning. For the axial scan, such thick slice images induced differences in the dose distribution between treatment planning and the actual situation. The helical scan with a small reconstructed increment reduced these differences even with relatively thick CT images. To achieve a more accurate dose distribution, radiation therapy planning should be performed using thin slice thickness for both scan methods or the helical scan with a small reconstructed increment. Although we reached this conclusion using the carbon beam, it may also be applied to proton beam therapy.
書誌情報 日本放射線技術学会雑誌

巻 61, 号 12, p. 1609-1615, 発行日 2005-12
ISSN
収録物識別子タイプ ISSN
収録物識別子 0369-4305
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:15:58.568543
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3