Development and performance evaluation of cone beam CT using video-fluoroscopic system

https://repo.qst.go.jp/records/44372
https://repo.qst.go.jp/records/44372
f3eb396e-95d6-48e3-bcfb-51667228fa6d
Item type 学術雑誌論文 / Journal Article(1)
公開日 2006-06-28
タイトル
タイトル Development and performance evaluation of cone beam CT using video-fluoroscopic system
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Endo, Masahiro

× Endo, Masahiro

WEKO 440915

Endo, Masahiro

Search repository
Yoshida, Katsuya

× Yoshida, Katsuya

WEKO 440916

Yoshida, Katsuya

Search repository
Kandatsu, Susumu

× Kandatsu, Susumu

WEKO 440917

Kandatsu, Susumu

Search repository
et.al

× et.al

WEKO 440918

et.al

Search repository
遠藤 真広

× 遠藤 真広

WEKO 440919

en 遠藤 真広

Search repository
吉田 勝哉

× 吉田 勝哉

WEKO 440920

en 吉田 勝哉

Search repository
神立 進

× 神立 進

WEKO 440921

en 神立 進

Search repository
抄録
内容記述タイプ Abstract
内容記述 We describe the development and performance evaluation of cone beam CT. This CT is based on video-fluoroscopic system and yields data that is amenable to three-dimensional (3D) image processing. An X-ray tube and a large area two-dimensional detector were mounted on a single frame and rotated around objects in 12 seconds. The large area detector consisted of a fluorescent plate and a charge coupled device (CCD) video camera. While the X-ray tube was rotated around the object, a pulsed X-ray was generated (30 pulses per second) and 360 projected images were collected in a 12-second scan. A 256x256x256 matrix image was reconstructed using a high-speed parallel processor with reconstruction time of 6 minutes. Image characteristics such as spatial resolution, image noise and distortion were evaluated by phantoms. The results showed isotropic spatial resolution and no distortion of images though they showed larger image noise than conventional CT.
書誌情報 CARS : Computer Assisted Radiology and Surgery : Proceedings of the International Congress and Exhibition

p. 497-500, 発行日 1998
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:16:13.649050
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3