ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Prototype heel effect compensation filter for cone-beam CT

https://repo.qst.go.jp/records/44346
https://repo.qst.go.jp/records/44346
c6be305f-2348-466f-99a2-26b0d5d8bc21
Item type 学術雑誌論文 / Journal Article(1)
公開日 2006-06-24
タイトル
タイトル Prototype heel effect compensation filter for cone-beam CT
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Mori, Shinichiro

× Mori, Shinichiro

WEKO 440542

Mori, Shinichiro

Search repository
Endo, Masahiro

× Endo, Masahiro

WEKO 440543

Endo, Masahiro

Search repository
Nishizawa, Kanae

× Nishizawa, Kanae

WEKO 440544

Nishizawa, Kanae

Search repository
Ohno, Mari

× Ohno, Mari

WEKO 440545

Ohno, Mari

Search repository
Miyazaki, Hiroaki

× Miyazaki, Hiroaki

WEKO 440546

Miyazaki, Hiroaki

Search repository
Tsujita, Kazuhiko

× Tsujita, Kazuhiko

WEKO 440547

Tsujita, Kazuhiko

Search repository
Saito, Yasuo

× Saito, Yasuo

WEKO 440548

Saito, Yasuo

Search repository
森 慎一郎

× 森 慎一郎

WEKO 440549

en 森 慎一郎

Search repository
遠藤 真広

× 遠藤 真広

WEKO 440550

en 遠藤 真広

Search repository
西澤 かな枝

× 西澤 かな枝

WEKO 440551

en 西澤 かな枝

Search repository
大野 真里

× 大野 真里

WEKO 440552

en 大野 真里

Search repository
抄録
内容記述タイプ Abstract
内容記述 The prototype cone-beam CT (CBCT) has a larger beam width than the conventional multi-detector row CT (MDCT). This causes a non-uniform angular distribution of the x-ray beam intensity known as the heel effect. Scan conditions for CBCT tube current are adjusted on the anode side to obtain an acceptable clinical image quality. However, as the dose is greater on the cathode side than on the anode side, the signal-to-noise ratio on the cathode side is excessively high, resulting in an unnecessary dose amount. To compensate for the heel effect, we developed a heel effect compensation (HEC) filter. The HEC filter rendered the dose distribution uniform and reduced the dose by an average of 25% for free air and by 20% for the CTDI phantoms compared to doses with the conventional filter. In addition, its effect in rendering the effective energy uniform resulted in an improvement in image quality. This new HEC filter may be useful in cone-beam CT study.
書誌情報 Physics in Medicine and Biology

巻 50, p. N359-N370, 発行日 2005-11
ISSN
収録物識別子タイプ ISSN
収録物識別子 0031-9155
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:16:32.748488
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3