ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Clinical potentials of the prototype 256-detector row CT-scanner1

https://repo.qst.go.jp/records/44341
https://repo.qst.go.jp/records/44341
279f0258-2c27-4edf-b621-2565da4bd7a1
Item type 学術雑誌論文 / Journal Article(1)
公開日 2006-06-24
タイトル
タイトル Clinical potentials of the prototype 256-detector row CT-scanner1
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Mori, Shinichiro

× Mori, Shinichiro

WEKO 440476

Mori, Shinichiro

Search repository
Endo, Masahiro

× Endo, Masahiro

WEKO 440477

Endo, Masahiro

Search repository
Obata, Takayuki

× Obata, Takayuki

WEKO 440478

Obata, Takayuki

Search repository
Murase, Kenya

× Murase, Kenya

WEKO 440479

Murase, Kenya

Search repository
Kandatsu, Susumu

× Kandatsu, Susumu

WEKO 440480

Kandatsu, Susumu

Search repository
Tanada, Shuji

× Tanada, Shuji

WEKO 440481

Tanada, Shuji

Search repository
森 慎一郎

× 森 慎一郎

WEKO 440482

en 森 慎一郎

Search repository
遠藤 真広

× 遠藤 真広

WEKO 440483

en 遠藤 真広

Search repository
小畠 隆行

× 小畠 隆行

WEKO 440484

en 小畠 隆行

Search repository
村瀬 研也

× 村瀬 研也

WEKO 440485

en 村瀬 研也

Search repository
神立 進

× 神立 進

WEKO 440486

en 神立 進

Search repository
棚田 修二

× 棚田 修二

WEKO 440487

en 棚田 修二

Search repository
抄録
内容記述タイプ Abstract
内容記述 Rationale and Objectives. To evaluate clinical potentials of the 256-detector row computed tomography (CT) in healthy volunteers.
Materials and Methods. Eight healthy males (22– 63 years) participated in the present study. They underwent a noncontrast-
enhanced examination with a contiguous axial scan mode either for head, chest, abdomen, or pelvis. Dose
was the same as routinely used for multislice CT examinations. Image quality was interpreted by three board-certi-
fied radiologists.
Results. With the 256-detector row CT, 0.5– 0.8 mm isotropic volumetric data could be acquired in one rotation. Main
promising findings are as follows. Three-dimensional structures were visualized clearly in the multiple planes without secondary
reconstruction, whereas the axial images had nearly the same image quality as conventional CT. Shading or streak
artifacts were observed at the edge of the scan region. The latter are also known as Feldkamp artifacts. Coronal chest images
showed a motion artifact from the heart beating.
Conclusion. The 256-detector row CT promises to be useful in clinical applications with its ability to provide three-dimensional
visualization of fine structures. The Feldkamp artifacts observed did not generally affect interpretation of images. Investigations
are now continuing on image correction along the craniocaudal direction to improve the overall image quality.
書誌情報 Academic Radiology

巻 12, 号 2, p. 148-154, 発行日 2005-02
ISSN
収録物識別子タイプ ISSN
収録物識別子 1076-6332
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:16:36.163496
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3