{"_buckets": {"deposit": "3d557f19-3608-4a9a-aaa0-3c234198fbea"}, "_deposit": {"created_by": 1, "id": "44341", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "44341"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00044341", "sets": ["1"]}, "author_link": ["440478", "440477", "440484", "440482", "440487", "440486", "440479", "440481", "440480", "440483", "440485", "440476"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2005-02", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "154", "bibliographicPageStart": "148", "bibliographicVolumeNumber": "12", "bibliographic_titles": [{"bibliographic_title": "Academic Radiology"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Rationale and Objectives. To evaluate clinical potentials of the 256-detector row computed tomography (CT) in healthy volunteers.\nMaterials and Methods. Eight healthy males (22\u0026#8211; 63 years) participated in the present study. They underwent a noncontrast-\nenhanced examination with a contiguous axial scan mode either for head, chest, abdomen, or pelvis. Dose\nwas the same as routinely used for multislice CT examinations. Image quality was interpreted by three board-certi-\nfied radiologists.\nResults. With the 256-detector row CT, 0.5\u0026#8211; 0.8 mm isotropic volumetric data could be acquired in one rotation. Main\npromising findings are as follows. Three-dimensional structures were visualized clearly in the multiple planes without secondary\nreconstruction, whereas the axial images had nearly the same image quality as conventional CT. Shading or streak\nartifacts were observed at the edge of the scan region. The latter are also known as Feldkamp artifacts. Coronal chest images\nshowed a motion artifact from the heart beating.\nConclusion. The 256-detector row CT promises to be useful in clinical applications with its ability to provide three-dimensional\nvisualization of fine structures. The Feldkamp artifacts observed did not generally affect interpretation of images. Investigations\nare now continuing on image correction along the craniocaudal direction to improve the overall image quality.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1076-6332", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Mori, Shinichiro"}], "nameIdentifiers": [{"nameIdentifier": "440476", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Endo, Masahiro"}], "nameIdentifiers": [{"nameIdentifier": "440477", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Obata, Takayuki"}], "nameIdentifiers": [{"nameIdentifier": "440478", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Murase, Kenya"}], "nameIdentifiers": [{"nameIdentifier": "440479", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kandatsu, Susumu"}], "nameIdentifiers": [{"nameIdentifier": "440480", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tanada, Shuji"}], "nameIdentifiers": [{"nameIdentifier": "440481", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "森 慎一郎", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "440482", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "遠藤 真広", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "440483", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小畠 隆行", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "440484", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "村瀬 研也", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "440485", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "神立 進", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "440486", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "棚田 修二", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "440487", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Clinical potentials of the prototype 256-detector row CT-scanner1", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Clinical potentials of the prototype 256-detector row CT-scanner1"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/44341", "pubdate": {"attribute_name": "公開日", "attribute_value": "2006-06-24"}, "publish_date": "2006-06-24", "publish_status": "0", "recid": "44341", "relation": {}, "relation_version_is_last": true, "title": ["Clinical potentials of the prototype 256-detector row CT-scanner1"], "weko_shared_id": -1}
Clinical potentials of the prototype 256-detector row CT-scanner1
https://repo.qst.go.jp/records/44341
https://repo.qst.go.jp/records/44341279f0258-2c27-4edf-b621-2565da4bd7a1
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-06-24 | |||||
タイトル | ||||||
タイトル | Clinical potentials of the prototype 256-detector row CT-scanner1 | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Mori, Shinichiro
× Mori, Shinichiro× Endo, Masahiro× Obata, Takayuki× Murase, Kenya× Kandatsu, Susumu× Tanada, Shuji× 森 慎一郎× 遠藤 真広× 小畠 隆行× 村瀬 研也× 神立 進× 棚田 修二 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Rationale and Objectives. To evaluate clinical potentials of the 256-detector row computed tomography (CT) in healthy volunteers. Materials and Methods. Eight healthy males (22– 63 years) participated in the present study. They underwent a noncontrast- enhanced examination with a contiguous axial scan mode either for head, chest, abdomen, or pelvis. Dose was the same as routinely used for multislice CT examinations. Image quality was interpreted by three board-certi- fied radiologists. Results. With the 256-detector row CT, 0.5– 0.8 mm isotropic volumetric data could be acquired in one rotation. Main promising findings are as follows. Three-dimensional structures were visualized clearly in the multiple planes without secondary reconstruction, whereas the axial images had nearly the same image quality as conventional CT. Shading or streak artifacts were observed at the edge of the scan region. The latter are also known as Feldkamp artifacts. Coronal chest images showed a motion artifact from the heart beating. Conclusion. The 256-detector row CT promises to be useful in clinical applications with its ability to provide three-dimensional visualization of fine structures. The Feldkamp artifacts observed did not generally affect interpretation of images. Investigations are now continuing on image correction along the craniocaudal direction to improve the overall image quality. |
|||||
書誌情報 |
Academic Radiology 巻 12, 号 2, p. 148-154, 発行日 2005-02 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1076-6332 |