WEKO3
アイテム
Volumetric cine imaging for cardiovascular circulation using prototype 256-detector row computed tomography scanner (4-dimensional computed tomography ) : A preliminary study with a porcine model
https://repo.qst.go.jp/records/44340
https://repo.qst.go.jp/records/44340e0fbead4-d071-47df-88f2-8ef25eac33fa
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-06-24 | |||||
タイトル | ||||||
タイトル | Volumetric cine imaging for cardiovascular circulation using prototype 256-detector row computed tomography scanner (4-dimensional computed tomography ) : A preliminary study with a porcine model | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Mori, Shinichiro
× Mori, Shinichiro× Kondo, Chisato× Suzuki, Naoki× Yamashita, Hiroyo× Kusakabe, Masahiro× Endo, Masahiro× 森 慎一郎× 近藤 千里× 鈴木 直樹× 山下 裕代× 日下部 正宏× 遠藤 真広 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Summary: This is a preliminary demonstration of volumetric cine imaging of cardiovascular circulation in domestic pigs using a prototype 256–detector row computed tomography (CT) scanner. The scan range is approximately 120 mm in the craniocaudal direction, with a 0.5-mm slice thickness. The thin sections can be used to create cine loops in multiple planes. Thus, the 256–detector row CT scanner overcomes some of the limitations of present helical CT methods. |
|||||
書誌情報 |
Journal of Computer Assisted Tomography 巻 29, 号 1, p. 26-30, 発行日 2005-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0363-8715 |