Comparison of patient doses in 256-slice CT and 16-slice CT scanners

https://repo.qst.go.jp/records/44335
https://repo.qst.go.jp/records/44335
8c62a2f3-0faa-4b90-b123-77c02a4827b2
Item type 学術雑誌論文 / Journal Article(1)
公開日 2006-06-23
タイトル
タイトル Comparison of patient doses in 256-slice CT and 16-slice CT scanners
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Mori, Shinichiro

× Mori, Shinichiro

WEKO 440393

Mori, Shinichiro

Search repository
Endo, Masahiro

× Endo, Masahiro

WEKO 440394

Endo, Masahiro

Search repository
Nishizawa, Kanae

× Nishizawa, Kanae

WEKO 440395

Nishizawa, Kanae

Search repository
Murase, Kenya

× Murase, Kenya

WEKO 440396

Murase, Kenya

Search repository
Fujiwara, Hideaki

× Fujiwara, Hideaki

WEKO 440397

Fujiwara, Hideaki

Search repository
Tanada, Shuji

× Tanada, Shuji

WEKO 440398

Tanada, Shuji

Search repository
森 慎一郎

× 森 慎一郎

WEKO 440399

en 森 慎一郎

Search repository
遠藤 真広

× 遠藤 真広

WEKO 440400

en 遠藤 真広

Search repository
西澤 かな枝

× 西澤 かな枝

WEKO 440401

en 西澤 かな枝

Search repository
村瀬 研也

× 村瀬 研也

WEKO 440402

en 村瀬 研也

Search repository
棚田 修二

× 棚田 修二

WEKO 440403

en 棚田 修二

Search repository
抄録
内容記述タイプ Abstract
内容記述 The 256-slice CT-scanner has been developed at National Institute of Radiological Sciences. Nominal beam width was 128 mm in the longitudinal direction. When scanning continuously at the same position to obtain four-dimensional (4D) images, the effective dose is increased in proportion to the scan time. Our purposes in this work were to measure the dose for the 256-slice CT, to compare it to that of the 16-slice CT-scanner, and to make a preliminary assessment of dose for dynamic 3D imaging (volumetric cine imaging). Our group reported previously that the phantom length and integration range for dosimetry needed to be at least 300 mm to represent more than 90 % of the line integral dose with the beam width between 20 mm and 138 mm. In order to obtain good estimates of the dose, we measured its line integral dose over a 300 mm range in PMMA (polymethylmethacrylate) phantoms of 160 mm or 320 mm diameter and 300 mm length. Doses for both CTs were compared for clinical protocol. The results showed that the 256-slice CT has smaller dose than the 16-slice CT in all examinations. The reason is the following: x-ray photons irradiated to the marginal portion near the slice collimator edge did not contribute to image formation, but they increased dose; the relative contribution of this portion was smaller for 256-slice CT than for 16-slice CT. Besides the 256-slice CT could take a large volume data in a one-rotation scan with sufficient image quality. For volumetric cine imaging, we found an acceptable scan time would be 6-11 s depending on examinations if dose must be limited to the same values as routine examinations with a conventional multi-detector CT. Finally, we discussed the studies necessary to make full usage of volumetric cine imaging.
書誌情報 British Journal of Radiology

巻 79, p. 56-61, 発行日 2006-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 0007-1285
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:16:40.457873
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3