Preliminary study of correction of original metal artifacts due to I-125 seeds in postimplant dosimetry for prostate permanent implant brachytherapy

https://repo.qst.go.jp/records/44334
https://repo.qst.go.jp/records/44334
0c9513a5-6f3e-4286-92a2-a5228bb89780
Item type 学術雑誌論文 / Journal Article(1)
公開日 2006-06-23
タイトル
タイトル Preliminary study of correction of original metal artifacts due to I-125 seeds in postimplant dosimetry for prostate permanent implant brachytherapy
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Takahashi, Yutaka

× Takahashi, Yutaka

WEKO 440386

Takahashi, Yutaka

Search repository
Mori, Shinichiro

× Mori, Shinichiro

WEKO 440387

Mori, Shinichiro

Search repository
Yamashita, Takashi

× Yamashita, Takashi

WEKO 440388

Yamashita, Takashi

Search repository
et.al

× et.al

WEKO 440389

et.al

Search repository
高橋 豊

× 高橋 豊

WEKO 440390

en 高橋 豊

Search repository
森 慎一郎

× 森 慎一郎

WEKO 440391

en 森 慎一郎

Search repository
山下 孝

× 山下 孝

WEKO 440392

en 山下 孝

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose: We investigated the method to correct CT metal artifacts due to I-125 seeds and evaluate this efficacy for postimplant dosimetry in prostate permanent implant brachytherapy.
Material and methods: The raw projection data was used to reduce metal artifacts due to I-125 seeds. The CT image of only metal parts was separated from original CT images by setting threshold for pixel value which corresponds to I-125 seeds. Using these images, the sinogram of CT images with or without seeds were obtained by inverse Radon transform. The sinogram of metal image was subtracted from that of the original image. Finally the image after metal artifact correction was reconstructed by Radon transform. This technique was applied to a prostate phantom and a patient.
Results: The metal artifact from I-125 seeds was reduced by our methods both in phantom and patient study. This technique made inner region of seeds dark while the edge of seeds remained white. Thus identification of seed number, orientation and locations could be easier.
Conclusion: Our method can be used to reduce metal artifacts from I-125 seeds and could be helpful to identify seeds, allowing speeding up and improving accuracy of postimplant dosimetry.
書誌情報 Radiation Medicine

巻 24, 号 2, p. 133-138, 発行日 2006-02
ISSN
収録物識別子タイプ ISSN
収録物識別子 0288-2043
戻る
0
views
See details
Views