  1. 原著論文

A comparative study of 11C-choline PET and [18F]fluorodeoxyglucose PET in the evaluation of lung cancer

https://repo.qst.go.jp/records/44280
https://repo.qst.go.jp/records/44280
d53a094a-4f6e-4956-bb4c-8325e0556d20
Item type 学術雑誌論文 / Journal Article(1)
公開日 2006-06-20
タイトル
タイトル A comparative study of 11C-choline PET and [18F]fluorodeoxyglucose PET in the evaluation of lung cancer
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Khan, N

× Khan, N

WEKO 439865

Khan, N

Search repository
Oriuchi, Noboru

× Oriuchi, Noboru

WEKO 439866

Oriuchi, Noboru

Search repository
Zhang, Hong

× Zhang, Hong

WEKO 439867

Zhang, Hong

Search repository
Higuchi, Tetsuya

× Higuchi, Tetsuya

WEKO 439868

Higuchi, Tetsuya

Search repository
Mei, Tian

× Mei, Tian

WEKO 439869

Mei, Tian

Search repository
Inoue, Tomio

× Inoue, Tomio

WEKO 439870

Inoue, Tomio

Search repository
Satou, Noriko

× Satou, Noriko

WEKO 439871

Satou, Noriko

Search repository
Endou, Keigo

× Endou, Keigo

WEKO 439872

Endou, Keigo

Search repository
張 宏

× 張 宏

WEKO 439873

en 張 宏

Search repository
井上 登美夫

× 井上 登美夫

WEKO 439874

en 井上 登美夫

Search repository
遠藤 啓吾

× 遠藤 啓吾

WEKO 439875

en 遠藤 啓吾

Search repository
抄録
内容記述タイプ Abstract
内容記述 The purpose of this study was to compare the diagnostic value of 11C-choline positron emission tomography (PET) and [18F]fluorodeoxyglucose (FDG) PET imaging in the detection of primary lung cancer and mediastinal lymph node metastases. Seventeen patients with histologically proven primary lung cancer were examined with both 11C-choline and FDG PET within a week of each study. Lung cancers were analysed visually and semiquantitatively using the ratio of tumour-to-normal radioactivity (T/N ratio) and standardized uptake value (SUV). Mediastinal lymph node metastases were analysed visually. Although both techniques delineated focal lesions with an increase intracer accumulation in 13 patients, FDG PET identified three additional patients in whom 11C-choline PET did not visualize any lesion. In the detection of lung cancer <2 cm in size, FDG PET provided higher sensitivity (six of seven, 85.7%) than 11C-choline PET (four of seven, 57.1%). THe T/N ratio and SUV were significantly higher with FDG PET (T/N ratio, 7.43 6.22, SUV, 4.05 3.05) than these were with 11C-choline PET (T/N ratio, 2.93 1.19, SUV, 2.93 0.79)(p<0.001). There was a significant positive correlation between tha T/N ratios and SUVs of FDG and 11C-choline. In the assessment of mediastinal lymph node involvement, FDG PET detected lymph node metastases in two patients who were negative on 11C-choline PET, whereas both techniques could not detect tumour involvement in one patient, Both techniques have clinical value for the non-invasive detection of primary lung cancer that is 2 cm or greater in size. However, FDG PET is superior to 11C-choline PET in the detection of lung cancer that is less than 2 cm in diameter and in mediastinal lymph node metastases.
書誌情報 Nuclear Medicine Communications

巻 24, p. 359-366, 発行日 2003
ISSN
収録物識別子タイプ ISSN
収録物識別子 0143-3636
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:17:20.512577
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3