WEKO3
アイテム
{"_buckets": {"deposit": "24514227-efe6-48fd-ba67-13d72080beaa"}, "_deposit": {"created_by": 1, "id": "44173", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "44173"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00044173", "sets": ["1"]}, "author_link": ["438933", "438930", "438923", "438925", "438928", "438931", "438932", "438929", "438922", "438927", "438926", "438924"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1998-07", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "8", "bibliographicPageStart": "1", "bibliographicVolumeNumber": "2", "bibliographic_titles": [{"bibliographic_title": "コンピュータ支援画像診断学会論文誌(Online Only URL:http://www.cadm.jp/journal/index.html;http://www.jstage.jst.go.jp/browse/cadm/_vols/-char/ja)"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "本報告では、肺がん検診用CT(Lung Cancer Screening CT: LSCT)検診支援システムの画像処理手法について報告する。このLSCTは1患者当たり約30枚の大量のデータが発生する難点がある。この問題点の解決として、我々は画像処理手法によって医師は提示する画像情報を減らす試みをしている。そこで、我々は以下の2つの手法を並列に用いた診断支援システムを検討し、良好な結果が得られた。(1)約30スライスからなる3次元情報を病巣の情報を損なうことなく2次元面に投影する画像前処理付きMIP表示方式。(2)病巣陰影候補を自動認識し、陰影候補の見つかったCT断面のみをデイスプレイすることにより、表示画面数を大幅に削減する方式。この病巣自動認識には、我々が新たに開発した可変N-Qunoit処理を用いた。", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1347-9245", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "奥村, 俊昭"}], "nameIdentifiers": [{"nameIdentifier": "438922", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "三輪, 倫子"}], "nameIdentifiers": [{"nameIdentifier": "438923", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "加古, 純一"}], "nameIdentifiers": [{"nameIdentifier": "438924", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山本, 眞司"}], "nameIdentifiers": [{"nameIdentifier": "438925", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松本, 満臣"}], "nameIdentifiers": [{"nameIdentifier": "438926", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "舘野, 之男"}], "nameIdentifiers": [{"nameIdentifier": "438927", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "飯沼, 武"}], "nameIdentifiers": [{"nameIdentifier": "438928", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松本, 徹"}], "nameIdentifiers": [{"nameIdentifier": "438929", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "その他"}], "nameIdentifiers": [{"nameIdentifier": "438930", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "舘野 之男", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "438931", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "飯沼 武", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "438932", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松本 徹", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "438933", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "肺がん検診用CT(LSCT)の診断支援システム", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "肺がん検診用CT(LSCT)の診断支援システム"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/44173", "pubdate": {"attribute_name": "公開日", "attribute_value": "2006-06-06"}, "publish_date": "2006-06-06", "publish_status": "0", "recid": "44173", "relation": {}, "relation_version_is_last": true, "title": ["肺がん検診用CT(LSCT)の診断支援システム"], "weko_shared_id": -1}
肺がん検診用CT(LSCT)の診断支援システム
https://repo.qst.go.jp/records/44173
https://repo.qst.go.jp/records/441735133c9a4-24fb-4b15-aaa0-84850d4d8fc0
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-06-06 | |||||
タイトル | ||||||
タイトル | 肺がん検診用CT(LSCT)の診断支援システム | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
奥村, 俊昭
× 奥村, 俊昭× 三輪, 倫子× 加古, 純一× 山本, 眞司× 松本, 満臣× 舘野, 之男× 飯沼, 武× 松本, 徹× その他× 舘野 之男× 飯沼 武× 松本 徹 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 本報告では、肺がん検診用CT(Lung Cancer Screening CT: LSCT)検診支援システムの画像処理手法について報告する。このLSCTは1患者当たり約30枚の大量のデータが発生する難点がある。この問題点の解決として、我々は画像処理手法によって医師は提示する画像情報を減らす試みをしている。そこで、我々は以下の2つの手法を並列に用いた診断支援システムを検討し、良好な結果が得られた。(1)約30スライスからなる3次元情報を病巣の情報を損なうことなく2次元面に投影する画像前処理付きMIP表示方式。(2)病巣陰影候補を自動認識し、陰影候補の見つかったCT断面のみをデイスプレイすることにより、表示画面数を大幅に削減する方式。この病巣自動認識には、我々が新たに開発した可変N-Qunoit処理を用いた。 | |||||
書誌情報 |
コンピュータ支援画像診断学会論文誌(Online Only URL:http://www.cadm.jp/journal/index.html;http://www.jstage.jst.go.jp/browse/cadm/_vols/-char/ja) 巻 2, 号 3, p. 1-8, 発行日 1998-07 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1347-9245 |