ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Sample storage conditions and holding times for the determination of total iodine in natural water samples by ICP-MS

https://repo.qst.go.jp/records/44097
https://repo.qst.go.jp/records/44097
b6b7cd14-c95e-4fcc-abce-cac0f5913311
Item type 学術雑誌論文 / Journal Article(1)
公開日 2006-05-29
タイトル
タイトル Sample storage conditions and holding times for the determination of total iodine in natural water samples by ICP-MS
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Tagami, Keiko

× Tagami, Keiko

WEKO 438376

Tagami, Keiko

Search repository
Uchida*, Shigeo

× Uchida*, Shigeo

WEKO 438377

Uchida*, Shigeo

Search repository
田上 恵子

× 田上 恵子

WEKO 438378

en 田上 恵子

Search repository
内田 滋夫

× 内田 滋夫

WEKO 438379

en 内田 滋夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 The determination of total soluble iodine concentration in fresh water by inductively coupled plasma mass spectrometry (ICP-MS) is simple and easy because no complicated pretreatment is needed; however, not all analysts have easy access to this instrumentation because it is expensive and has high running costs. In this study, sample storage conditions and holding times were examined for total soluble iodine measurement in standard and three river water samples by ICP-MS to provide more favorable circumstances for users.
When standard solutions were stored at room temperature, the determined iodine at day 21 decreased by ca. 20% in the samples without adding an alkaline reagent, such as tetramethyl ammonium hydroxide (TMAH), probably due to I2 release from the solution. However, with the addition of a small amount of TMAH, iodine was retained in the solution and no decrease was observed. When the samples were stored at 5?, however, it was not necessary to add an alkaline reagent; for example, measured total iodine concentrations did not change for six months. Besides, measured total iodine concentrations in river water samples stored at 5? did not change for almost one year. The concentrations of total iodine in the three Japanese rivers (10 samples per each river) were all measured, and the concentration ranged from 0.33 to 3.87 micro g L-1, with an average of 1.16 micro g L-1.
書誌情報 Atomic Scpectroscopy

巻 26, 号 6, p. 209-214, 発行日 2005-12
ISSN
収録物識別子タイプ ISSN
収録物識別子 0195-5373
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:19:27.020970
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3