DESIGN AND IMPLEMENTATION OF A RADIOTHERAPY DATABASE IN CARBON ION THERAPY

https://repo.qst.go.jp/records/43970
https://repo.qst.go.jp/records/43970
525fc776-58db-4140-b7d2-6561fbaaae5f
Item type 学術雑誌論文 / Journal Article(1)
公開日 2006-01-20
タイトル
タイトル DESIGN AND IMPLEMENTATION OF A RADIOTHERAPY DATABASE IN CARBON ION THERAPY
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Koyama-Ito, Hiroko

× Koyama-Ito, Hiroko

WEKO 437116

Koyama-Ito, Hiroko

Search repository
Endo, Masahiro

× Endo, Masahiro

WEKO 437117

Endo, Masahiro

Search repository
Ito, Akira

× Ito, Akira

WEKO 437118

Ito, Akira

Search repository
Mizoe, Junetsu

× Mizoe, Junetsu

WEKO 437119

Mizoe, Junetsu

Search repository
Tsujii, Hirohiko

× Tsujii, Hirohiko

WEKO 437120

Tsujii, Hirohiko

Search repository
伊藤 浩子

× 伊藤 浩子

WEKO 437121

en 伊藤 浩子

Search repository
遠藤 真広

× 遠藤 真広

WEKO 437122

en 遠藤 真広

Search repository
伊藤 彬

× 伊藤 彬

WEKO 437123

en 伊藤 彬

Search repository
溝江 純悦

× 溝江 純悦

WEKO 437124

en 溝江 純悦

Search repository
辻井 博彦

× 辻井 博彦

WEKO 437125

en 辻井 博彦

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purposes: To report on the design and implementation of a database system that provides access to the radiotherapy (RT) data for the purpose of data analysis in a clinical trial of carbon ion radiotherapy at National Institute of Radiological Sciences.
Methods and Materials: The data stored in this system are the patient treatment planning and record data including non-volumetric data of character and numerical type (1), and 2D or 3D volumetric data sets of CT images, target and organ contours, apertures and range compensators, dose distributions and simulation radiographs (2). Two subsystems were prepared for respective data type. One is a therapy information database that stores non-volumetric data (1), which can be accessed with client applications working on personal computers (PCs). Another is a DICOM RT archive that stores volumetric data sets (2) as DICOM RT data objects. The archive allows on-line data access with a developed application, RT viewer that works on PCs. Queried data sets can be displayed and downloaded as DICOM files or AAPM/RTOG Data Exchange format files. All the data sets are loaded into the system on-line daily at specified time.
Results: The system has operated for over two years and during this period we repaired and improved the applications. Presently it operates stably and it has been loaded with the data sets of more than 2000 patients treated since 1994. User applications are described with some examples.
Conclusion: The system enables users to analyze the therapy data for evaluation of treatment results. It provides volumetric data in portable format for further image-based analyses.
書誌情報 Journal of the Japanese Society for Therapeutic Radiology and Oncology

巻 17, 号 3, p. 161-168, 発行日 2005-09
ISSN
収録物識別子タイプ ISSN
収録物識別子 1040-9564
戻る
0
views
See details
Views