Neutron irradiation field produced by 25 MeV deuterons bombarding on thick beryllium target for radiobiological study

https://repo.qst.go.jp/records/43965
https://repo.qst.go.jp/records/43965
53e749aa-3bf8-48a9-8573-313b02ea6d52
Item type 学術雑誌論文 / Journal Article(1)
公開日 2006-01-16
タイトル
タイトル Neutron irradiation field produced by 25 MeV deuterons bombarding on thick beryllium target for radiobiological study
言語
言語 jpn
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 高田, 真志

× 高田, 真志

WEKO 437065

高田, 真志

Search repository
三原, 恵里香

× 三原, 恵里香

WEKO 437066

三原, 恵里香

Search repository
中村, 尚司

× 中村, 尚司

WEKO 437067

中村, 尚司

Search repository
藤高, 和信

× 藤高, 和信

WEKO 437068

藤高, 和信

Search repository
その他

× その他

WEKO 437069

その他

Search repository
高田 真志

× 高田 真志

WEKO 437070

en 高田 真志

Search repository
中村 尚司

× 中村 尚司

WEKO 437071

en 中村 尚司

Search repository
藤高 和信

× 藤高 和信

WEKO 437072

en 藤高 和信

Search repository
抄録
内容記述タイプ Abstract
内容記述 A fast neutron irradiation field for biological studies was established at the cyclotron facility in the National Institute of Radiological Sciences. Neutron spatial distributions and absorbed dose distributions were measured to characterize the netron field. By using a simple technique that an aluminum plate activated by neutrons was exposed the imaging plates, the width if the neutron-irradiated area was measured to be 23.6cm with 2.5mm spatial resolution. The absorbed dose distributions of neutrions and γ rays were obrained separately by using a tissue-eqivalent plastic-and a graphite-walled low-pressure proportional counter. The neutron absorbed dose in a tissue-equivalent plastic was measured to be 144.6(Gy/C). It was confirmed that this neutron field has only 1.8% contamination of γ ray dose and has good quality for neutron irradiaton to biological samples.
書誌情報 Nuclear Instruments & Methods in Physics Research Section A

巻 545, p. 765-775, 発行日 2005
ISSN
収録物識別子タイプ ISSN
収録物識別子 0168-9002
戻る
0
views
See details
Views