ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Magnetic resonance imaging of molecular transport in living morning glory stems.

https://repo.qst.go.jp/records/43878
https://repo.qst.go.jp/records/43878
8fef2d6d-0f91-407a-b3b0-66f6fefe4859
Item type 学術雑誌論文 / Journal Article(1)
公開日 2005-12-14
タイトル
タイトル Magnetic resonance imaging of molecular transport in living morning glory stems.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Osuga, Toshiaki

× Osuga, Toshiaki

WEKO 436244

Osuga, Toshiaki

Search repository
et.al

× et.al

WEKO 436245

et.al

Search repository
大須賀 敏明

× 大須賀 敏明

WEKO 436246

en 大須賀 敏明

Search repository
抄録
内容記述タイプ Abstract
内容記述 MRI was applied to investigate the transport pathways in Morning Glory plant stems. The study was carried out on living plants without affecting their integrity. The architecture of a dicotyledonous plant was deeply characterized: the root system structure and the vascular bundle location were identified, the presence of central voids caused by cell maturation and loss were observed in the stem. Molecular transport components were recognized, by observing the concentration profile of a tracer, which changed with time after its absorption by the plant roots. MRI analysis revealed the presence of an axial transport as the progress of the tracer front through the vascular bundles and a radial molecular transport from the vascular bundles toward the surface of the stem. As a result, the tracer molecular transport formed the parabolic tracer front (PTF). A model was built up through the analysis of the PTF that consisted of an axial front at the peak position and a radial front at the width of the parabolic tail. PTF analysis revealed differences between the tracer transport velocities in the axial and the radial directions in the plant stem. The model revealed that the width of the parabolic tail reflected the magnitudes of diffusion and permeation of the tracer in the plant stem.
書誌情報 Magnetic Resonance Imaging

巻 19, 号 10, p. 1311-1322, 発行日 2001-12
ISSN
収録物識別子タイプ ISSN
収録物識別子 0730-725X
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:22:00.613858
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3