Verification of the dose distributions with GEANT4 simulation for proton therapy

https://repo.qst.go.jp/records/43858
https://repo.qst.go.jp/records/43858
78d7caf7-e1d2-40cf-88b5-b647444dc5e2
Item type 学術雑誌論文 / Journal Article(1)
公開日 2005-11-30
タイトル
タイトル Verification of the dose distributions with GEANT4 simulation for proton therapy
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Aso, Tsukasa

× Aso, Tsukasa

WEKO 436043

Aso, Tsukasa

Search repository
Kanematsu, Nobuyuki

× Kanematsu, Nobuyuki

WEKO 436044

Kanematsu, Nobuyuki

Search repository
et.al

× et.al

WEKO 436045

et.al

Search repository
兼松 伸幸

× 兼松 伸幸

WEKO 436046

en 兼松 伸幸

Search repository
抄録
内容記述タイプ Abstract
内容記述 A GEANT4-based simulation of an irradiation system for proton therapy has been developed for the verification of dose distributions. The simulation represents the treatment room and beam irradiation system at the Hyogo Ion Beam Medical Center (HIBMC). The beam irradiation system consists of a lateral beam-spreading system and a range modulating system, which enable a three-dimensional dose distribution to be achieved. The simulation was carried out for proton beams at the isocentric gantry nozzle for therapeutic energies of 150, 190, and 230 MeV. The simulated distributions were compared to measured dose distributions obtained by using a water phantom at the isocenter. This arrangement simulates the practical aspects of the beam irradiation of a patient.
The validation of the simulation was performed in proton range for important materials in the beam line, and in the lateral uniformity of the radiation field at the isocenter. Dose distributions based on GEANT4 were verified with measurements of the Bragg peak and the spread-out Bragg peak. This verification shows that the simulations are in good agreement with measurements.
書誌情報 IEEE Transactions on Nuclear Science

巻 52, 号 4, p. 896-901, 発行日 2005-08
ISSN
収録物識別子タイプ ISSN
収録物識別子 0018-9499
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:22:14.417723
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3