ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

The Response of the silicon-based Linear Energy Transfer Spectrometer (RRMD-III) to Protons from 1 to 70 MeV

https://repo.qst.go.jp/records/43839
https://repo.qst.go.jp/records/43839
1ca40a8f-0001-44b5-bdaf-1c546100bd13
Item type 学術雑誌論文 / Journal Article(1)
公開日 2005-11-03
タイトル
タイトル The Response of the silicon-based Linear Energy Transfer Spectrometer (RRMD-III) to Protons from 1 to 70 MeV
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Terasawa, Kazuhiro

× Terasawa, Kazuhiro

WEKO 435844

Terasawa, Kazuhiro

Search repository
Doke, Tadayoshi

× Doke, Tadayoshi

WEKO 435845

Doke, Tadayoshi

Search repository
Fuse, Tetsuhito

× Fuse, Tetsuhito

WEKO 435846

Fuse, Tetsuhito

Search repository
Kitamura, Hisashi

× Kitamura, Hisashi

WEKO 435847

Kitamura, Hisashi

Search repository
Uchihori, Yukio

× Uchihori, Yukio

WEKO 435848

Uchihori, Yukio

Search repository
et.al

× et.al

WEKO 435849

et.al

Search repository
寺沢 和洋

× 寺沢 和洋

WEKO 435850

en 寺沢 和洋

Search repository
道家 忠義

× 道家 忠義

WEKO 435851

en 道家 忠義

Search repository
布施 哲人

× 布施 哲人

WEKO 435852

en 布施 哲人

Search repository
北村 尚

× 北村 尚

WEKO 435853

en 北村 尚

Search repository
内堀 幸夫

× 内堀 幸夫

WEKO 435854

en 内堀 幸夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 Experiments have been performed to measure the response of the silicon-based linear energy transfer (LET) spectrometer (RRMD-III) to protons with energies ranging from 1 to 70 MeV. The beam energies incident upon RRMD-III were obtained using plastic polycarbonate degraders with mono-energetic proton beams that were extracted at 70, 40 and 25 MeV from a cyclotron. The energy loss in the degraders never exceed 70% of the incident energy in order that the energy spread of the emerging protons created by straggling and scattering effects could be sppressed. Estimates of the LET were influenced by the asymmetric energy distribution of the degraded beam. Protons with energies less than 12.2 MeV did not reach the second Si detector in RRMD-III and were not measured. Measured values of LET were within +-7% of the expected value for incident particles was computed using a lookup table listing LET vs E, and a simple stopping power formula for a particle with charge Z and energy Er, where Er is the energy of the stopping particle measured in the second Si detector.
書誌情報 Japanese Journal of Applied Physics

巻 44, 号 10, p. 7608-7613, 発行日 2005-10
ISSN
収録物識別子タイプ ISSN
収録物識別子 0021-4922
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:22:27.827029
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3