  1. 原著論文

Efficacies of three chelating agents on removal of plutonium in rats: comparison of CBMIDA, 3,4,3-LIHOPO and Ca-DTPA

https://repo.qst.go.jp/records/43760
https://repo.qst.go.jp/records/43760
b5efce9f-784a-4244-a73e-6f071fd6e310
Item type 学術雑誌論文 / Journal Article(1)
公開日 2005-08-10
タイトル
タイトル Efficacies of three chelating agents on removal of plutonium in rats: comparison of CBMIDA, 3,4,3-LIHOPO and Ca-DTPA
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Fukuda, Satoshi

× Fukuda, Satoshi

WEKO 435088

Fukuda, Satoshi

Search repository
Iida, Haruzo

× Iida, Haruzo

WEKO 435089

Iida, Haruzo

Search repository
Yan, Xueming

× Yan, Xueming

WEKO 435090

Yan, Xueming

Search repository
Xie, Yuyuan

× Xie, Yuyuan

WEKO 435091

Xie, Yuyuan

Search repository
Burgda, Roman

× Burgda, Roman

WEKO 435092

Burgda, Roman

Search repository
Bailly, Theodorine

× Bailly, Theodorine

WEKO 435093

Bailly, Theodorine

Search repository
福田 俊

× 福田 俊

WEKO 435094

en 福田 俊

Search repository
飯田 治三

× 飯田 治三

WEKO 435095

en 飯田 治三

Search repository
抄録
内容記述タイプ Abstract
内容記述 The effects of three chelating agents, CBMIDA, 3,4,3-LIHOPO, and Ca-DTPA, for removing Pu-239 in rats were compared. Forty female Wistar rats, 2 months old, were pre-injected intraperitoneally with 37,000Bq/kg of plutonium nitrate and divided into four groups. Thereafter the rats of three groups were injected intraperitoneally with three chelating agents at a dose of 30mmol/kg, equivalent to a daily recommended human dose of Ca-DTPA, at intervals of 24hr for 3 days, beginning 30 min after plutonium injection on the first day of treatment. Urine and feces were collected every 24 hr. On day 4, the rats were sacrificed to obtain organs including the liver, kidney, and spleen, as well as the femur and serum. The amounts of excreted plutonium in urine of the CBMIDA and Ca-DTPA groups were increased significantly over that in the 3,4,3-LIHOPO and control groups, while those in the feces of the 3,4,3-LIHOPO group were increased significantly over the other groups on the first day. The total amount of excreted plutonium by 3 day-treatments was highest in the 3,4,3-LIHOPO group. The toxicity of each agent was discussed. It is concluded that at the same doses, the effect of 3,4,3-LIHOPO was superior to CBMIDA and Ca-DTPA for removing plutonium in rats.
書誌情報 Japanese Journal of Health Physics

巻 38, 号 1, p. 62-67, 発行日 2003-05
ISSN
収録物識別子タイプ ISSN
収録物識別子 0367-6110
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:23:22.745629
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3