ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

The measurement of the fragment emission angles in the reactions of < 135 MeV/u 12C and 16O in tissue equivalent targets

https://repo.qst.go.jp/records/43702
https://repo.qst.go.jp/records/43702
2108b380-7217-420a-8041-b95f7c2f78ec
Item type 学術雑誌論文 / Journal Article(1)
公開日 2005-06-21
タイトル
タイトル The measurement of the fragment emission angles in the reactions of < 135 MeV/u 12C and 16O in tissue equivalent targets
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 M, Giacomelli

× M, Giacomelli

WEKO 434522

M, Giacomelli

Search repository
Skvarc, J

× Skvarc, J

WEKO 434523

Skvarc, J

Search repository
Ilic, Rodomir

× Ilic, Rodomir

WEKO 434524

Ilic, Rodomir

Search repository
Yasuda, Nakahiro

× Yasuda, Nakahiro

WEKO 434525

Yasuda, Nakahiro

Search repository
et.al

× et.al

WEKO 434526

et.al

Search repository
安田 仲宏

× 安田 仲宏

WEKO 434527

en 安田 仲宏

Search repository
抄録
内容記述タイプ Abstract
内容記述 Different stacks of tissue equivalent targets interleaved with CR-39 nuclear track detectors were irradiated with 135 MeV/u 12C and 16O ions. After track etching and measurement by an automatic image analysis system, a method of trajectory tracing was applied. The trajectories of particles were reconstructed using a pattern-matching method based on a comparison of relative track coordinates.
\nFragmentation products have a lower charge and can be clearly distinguished by their smaller track sizes. The track positions within the individual trajectory are additionally fitted to a straight line, from which we can determine the direction of the traversing ion within a path of a few mm. We performed an angular distribution study of the fragments, which we compared to simulation results obtained by a simple particle emission model. For the fitted parameters the model showed agreement within the margins of error but failed to describe the energy dependence and thus should be further improved and upgraded.
書誌情報 Radiation Measurements

巻 36, p. 329-334, 発行日 2003-06
ISSN
収録物識別子タイプ ISSN
収録物識別子 1350-4487
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:24:05.978793
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3