ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Experimental evaluation of analytical penumbra calculation model for wobbled beams

https://repo.qst.go.jp/records/43659
https://repo.qst.go.jp/records/43659
a1a3936a-b5d6-4201-9f50-79835fb95231
Item type 学術雑誌論文 / Journal Article(1)
公開日 2005-05-12
タイトル
タイトル Experimental evaluation of analytical penumbra calculation model for wobbled beams
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kohno, Ryosuke

× Kohno, Ryosuke

WEKO 434093

Kohno, Ryosuke

Search repository
Kanematsu, Nobuyuki

× Kanematsu, Nobuyuki

WEKO 434094

Kanematsu, Nobuyuki

Search repository
Yusa, Ken

× Yusa, Ken

WEKO 434095

Yusa, Ken

Search repository
Kanai, Tatsuaki

× Kanai, Tatsuaki

WEKO 434096

Kanai, Tatsuaki

Search repository
河野 良介

× 河野 良介

WEKO 434097

en 河野 良介

Search repository
兼松 伸幸

× 兼松 伸幸

WEKO 434098

en 兼松 伸幸

Search repository
遊佐 顕

× 遊佐 顕

WEKO 434099

en 遊佐 顕

Search repository
金井 達明

× 金井 達明

WEKO 434100

en 金井 達明

Search repository
抄録
内容記述タイプ Abstract
内容記述 The goal of radiotherapy is not only to apply a high radiation dose to a tumor, but also to avoid side effects in the surrounding healthy tissue. Therefore, it is important for carbon-ion treatment planning to calculate accurately the effects of the lateral penumbra. In this article, for wobbled beams under various irradiation conditions, we focus on the lateral penumbras at several aperture positions of one side leaf of the multileaf collimator. The penumbras predicted by an analytical penumbra calculation model were compared with the measured results. The results calculated by the model for various conditions agreed well with the experimental ones. In conclusion, we found that the analytical penumbra calculation model could predict accurately the measured results for wobbled beams and it was useful for carbon-ion treatment planning to apply the model.
書誌情報 Medical Physics

巻 31, 号 5, p. 1153-1157, 発行日 2004-05
ISSN
収録物識別子タイプ ISSN
収録物識別子 0094-2405
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:24:36.140578
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3