ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Determination of Plutonium and its isotopic ratio in marine sediment samples using quadrupole ICP-MS with shield torch system under normal plasma conditions

https://repo.qst.go.jp/records/43616
https://repo.qst.go.jp/records/43616
36cc3696-05ab-4d8a-8b52-27fe5d5417b0
Item type 学術雑誌論文 / Journal Article(1)
公開日 2005-01-13
タイトル
タイトル Determination of Plutonium and its isotopic ratio in marine sediment samples using quadrupole ICP-MS with shield torch system under normal plasma conditions
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Zheng, Jian

× Zheng, Jian

WEKO 433671

Zheng, Jian

Search repository
Yamada, Masatoshi

× Yamada, Masatoshi

WEKO 433672

Yamada, Masatoshi

Search repository
Zhonglian, Wang

× Zhonglian, Wang

WEKO 433673

Zhonglian, Wang

Search repository
Aono, Tatsuo

× Aono, Tatsuo

WEKO 433674

Aono, Tatsuo

Search repository
Kusakabe, Masashi

× Kusakabe, Masashi

WEKO 433675

Kusakabe, Masashi

Search repository
鄭 建

× 鄭 建

WEKO 433676

en 鄭 建

Search repository
山田 正俊

× 山田 正俊

WEKO 433677

en 山田 正俊

Search repository
王 中良

× 王 中良

WEKO 433678

en 王 中良

Search repository
青野 辰雄

× 青野 辰雄

WEKO 433679

en 青野 辰雄

Search repository
日下部 正志

× 日下部 正志

WEKO 433680

en 日下部 正志

Search repository
抄録
内容記述タイプ Abstract
内容記述 An analytical method for 239Pu and 240Pu in marine sediment samples which uses quadrupole ICP-MS was developed in this work. A simple anion-exchange chromatography system was employed for the separation and purification of Pu from the sample matrix. A sufficient decontamination factor of 14000 for U, which interferes with the determination of 239Pu, was achieved. High sensitivity for Pu determination was obtained, which led to an extremely low concentration detection limit of ca. 8 fg/ml (0.019 mBq/ml for 239Pu; 0.071 mBq/ml for 240Pu) in a sample solution or an absolute detection limit of 42 fg in 5 ml sample solution by using the shield torch technique. Analytical results of 239+240Pu and 240Pu/239Pu ratio in IAEA 368 (ocean sediment) reference material indicated that the accuracy of the method was satisfactory. The developed method was successfully applied to a study on Pu behavior in the sediments from Sagami Bay, Japan. The observed high 240Pu/239Pu ratio in the sediment core indicated that there was additional Pu input derived from close-in fallout in addition to the global fallout.
書誌情報 Analytical and Bioanalytical Chemistry

巻 379, p. 532-539, 発行日 2004-06
出版者
出版者 Springer
ISSN
収録物識別子タイプ ISSN
収録物識別子 1618-2642
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:25:06.698375
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3