ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Attempt at In-air-PIXE Analysis of Spot Samples on a Filter-tape Mounted in an Automated Beta-ray Absorption Mass Monitor

https://repo.qst.go.jp/records/43569
https://repo.qst.go.jp/records/43569
fbf2991f-098d-49c5-8347-5257916d2cb9
Item type 学術雑誌論文 / Journal Article(1)
公開日 2004-12-17
タイトル
タイトル Attempt at In-air-PIXE Analysis of Spot Samples on a Filter-tape Mounted in an Automated Beta-ray Absorption Mass Monitor
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Katsumi, Saitou

× Katsumi, Saitou

WEKO 433188

Katsumi, Saitou

Search repository
Imaseki, Hitoshi

× Imaseki, Hitoshi

WEKO 433189

Imaseki, Hitoshi

Search repository
Yukawa, Masae

× Yukawa, Masae

WEKO 433190

Yukawa, Masae

Search repository
今関 等

× 今関 等

WEKO 433191

en 今関 等

Search repository
湯川 雅枝

× 湯川 雅枝

WEKO 433192

en 湯川 雅枝

Search repository
抄録
内容記述タイプ Abstract
内容記述 We attempted in-air-PIXE analysis of SPM using spot samples on a filter-tape mounted in an automated beta-ray absorption mass monitor. Al, Si, S, Fe and Zn etc., which are of interest for identifying the behavior and characteristics of SPM, were detected on the SPM spot samples on a glass-fiber filter-tape, but the peaks of these elements were nearly identical to those of blank glass-fiber filter-tape. As such, it was difficult to detect elements present in SPM from the X-ray spectra of the spot samples. On the other hand, in the case of a PTFE membrane filter-tape, the S peak was distinct and the Fe peak was also clear, and peaks for elements Al, Mn and Zn, etc., were also confirmed. Consequently, if a method for determining quantity is established, direct multi-elemental analysis by in-air-PIXE of high time-resolution SPM spot samples collected on a PTFE membrane filter-tape mounted in a SPM monitor will be possible.
書誌情報 International Journal of PIXE

巻 14, 号 1/2, p. 43-48, 発行日 2004
ISSN
収録物識別子タイプ ISSN
収録物識別子 0129-0835
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:25:40.352560
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3