ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Proton magnetic resonance imaging of flow motion of heavy water injected into a hollow fiber dialyzer filled with saline

https://repo.qst.go.jp/records/43562
https://repo.qst.go.jp/records/43562
60f14b65-104b-4651-ba3a-1c872c5f4c44
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2004-12-14
タイトル
タイトル Proton magnetic resonance imaging of flow motion of heavy water injected into a hollow fiber dialyzer filled with saline
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Osuga, Toshiaki

× Osuga, Toshiaki

WEKO 433148

Osuga, Toshiaki

Search repository
Obata, Takayuki

× Obata, Takayuki

WEKO 433149

Obata, Takayuki

Search repository
Ikehira, Hiroo

× Ikehira, Hiroo

WEKO 433150

Ikehira, Hiroo

Search repository
大須賀 敏明

× 大須賀 敏明

WEKO 433151

en 大須賀 敏明

Search repository
小畠 隆行

× 小畠 隆行

WEKO 433152

en 小畠 隆行

Search repository
池平 博夫

× 池平 博夫

WEKO 433153

en 池平 博夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 Observations using MRI were performed for the motion of heavy water injected into a hollow fiber dialyzer. A cylindrical dialyzer houses a bundle of 10,000 hollowe fibers. Because blood components permeate through the hollow fiber membrane from the interior to the exterior of the hollow fiber, which is the dialysate flow path uniformity of dialysate flow is required. The dialyzer was initially filled with saline and heavy water was injected into the inlet port of the dialysate flow path. MRI tuned for protons could distinguish the injected heavy water from the already present saline. Due to the specific gravity difference, MRI could observe the sedimentation of the injected heavy water flowing beneath the already present saline. The uniformity of the dialysate flow was supported by the finding that the injected heavy water brought about uniform sedimenation and distributed the already present saline uniformly throughout the entire volume of the dialyzer.
書誌情報 Magnetic Resonance Imaging

巻 22, 号 3, p. 413-416, 発行日 2004-04
ISSN
収録物識別子タイプ ISSN
収録物識別子 0730-725X
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:25:45.192612
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3