ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Corss-calibration of ionization chambers in proton and carbon beams

https://repo.qst.go.jp/records/43503
https://repo.qst.go.jp/records/43503
ec8d7a40-cbf4-480c-90c9-a02b02ea1a54
Item type 学術雑誌論文 / Journal Article(1)
公開日 2004-10-13
タイトル
タイトル Corss-calibration of ionization chambers in proton and carbon beams
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kanai, Tatsuaki

× Kanai, Tatsuaki

WEKO 432599

Kanai, Tatsuaki

Search repository
Fukumura, Akifumi

× Fukumura, Akifumi

WEKO 432600

Fukumura, Akifumi

Search repository
Kusano, Yohsuke

× Kusano, Yohsuke

WEKO 432601

Kusano, Yohsuke

Search repository
Shinbo, Munefumi

× Shinbo, Munefumi

WEKO 432602

Shinbo, Munefumi

Search repository
Nishio, Teiji

× Nishio, Teiji

WEKO 432603

Nishio, Teiji

Search repository
金井 達明

× 金井 達明

WEKO 432604

en 金井 達明

Search repository
福村 明史

× 福村 明史

WEKO 432605

en 福村 明史

Search repository
新保 宗史

× 新保 宗史

WEKO 432606

en 新保 宗史

Search repository
西尾 禎治

× 西尾 禎治

WEKO 432607

en 西尾 禎治

Search repository
抄録
内容記述タイプ Abstract
内容記述 The calibration coefficinets of a parallel plate ionization chamber are examined by comparing the coefficients obtained through three methods: a calculation from a Co-60 calibration coefficient, N[D,w,Co-60], a cross-calibration of a parallel plate ionization chamber using a cylindrical ionization chamber at the plateau region of a mono-energetic beam and a cross-calibration of the chamber using a cylindrical chamber at the middle of the SOBP of the therapeutic beams, This paper also examines reference conditions for determining absorbed dose to water in the cases of therapeutic carbon and proton beams, In the dose calibration procedure recommended by IAEA, irradiation fields should be larger than 10 cm in diameter and the water phantom should extend by at least 5 cm beyond each side of the field. These recommendations are experimentally verified for proton and carbon beams. For proton beams, the calibration coefficients obtained by these three methods epproximately agreed. For carbon beams, the calibration coefficients obtained by the second method were about 1.0 % larger thanthose obtained by the third method, and the calibration coefficinets obtained by cross-calibration using 290 MeV/u beams were 0.5% lower than those obtained using 400 MeV/u beams. The calibration coefficinet obtained by the first method agreed roughly with the results obtained by SOBP beams.
書誌情報 Physics in Medicine and Biology

巻 49, p. 771-781, 発行日 2004-02
ISSN
収録物識別子タイプ ISSN
収録物識別子 0031-9155
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:26:32.764442
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3