ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Comparison of 11C-choline PET and FDG PET for the differential diagnosis of malignant tumors

https://repo.qst.go.jp/records/43462
https://repo.qst.go.jp/records/43462
0a9f0171-dad9-48ac-8d16-c8e039e5e5cf
Item type 学術雑誌論文 / Journal Article(1)
公開日 2004-08-11
タイトル
タイトル Comparison of 11C-choline PET and FDG PET for the differential diagnosis of malignant tumors
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Zhang, Hong

× Zhang, Hong

WEKO 432222

Zhang, Hong

Search repository
Oriuchi, Noboru

× Oriuchi, Noboru

WEKO 432223

Oriuchi, Noboru

Search repository
Higuchi, Tetsuya

× Higuchi, Tetsuya

WEKO 432224

Higuchi, Tetsuya

Search repository
Endou, Keigo

× Endou, Keigo

WEKO 432225

Endou, Keigo

Search repository
張 宏

× 張 宏

WEKO 432226

en 張 宏

Search repository
遠藤 啓吾

× 遠藤 啓吾

WEKO 432227

en 遠藤 啓吾

Search repository
抄録
内容記述タイプ Abstract
内容記述 We prospectively assessed and compared the usefulness of 11C-choline positron emission tomography (PET) with that of [18F]-2-fluoro-2-deoxy-D-glucose (FDG) PET for the differentiation between benign and malignant tumors. A total of 126 patients with 130 lesions were studied (25 brain tumors, 51 head and neck tumors, 15 bone tumors, 16 lung tumors, and 23 soft tissue tumors). 11C-choline PET and FDG PET were performed from 5 and 40 min, respectively, after injection of 275-370 MBq tracer. PET data were evaluated using the standardized uptake value (SUV) and were analyzed in accordance with the pathologic data. The 11C-choline uptake in malignancies was 3.9 2.3 (n =81), which was significantly higher than that in benign lesions (n =49) (2.6 1.7,P <0.005). The FDG uptake in malignancies was 5.9 3.8 (n =81) and was also significantly higher than that in benign lesions (2.8 2.0, P <0.0001). The 11C-choline uptake in the lesions correlated with FDG uptake (r =0.65, P <0.003).According to an ROC analysis, the areas under the ROC curves (AUCs) for 11C-choline PET were more than 0.8 in bone head and neck, lung, and soft tissue tumors, while the AUC was 0.79 in brain tumors. The AUCs for FDG PET were similarly more than 0.8 in bone, head and neck, lung, and soft tissue tumors, but had a lower value of 0.585 in brain tumors. In brain, head and neck, bone, and soft tissue tumors, 11C-choline showed higher contrast than FDG. In conclusion, it is feasible to use 11C-choline PET for differentiation between malignant and benign tumours, especially of the brain, head ad neck, bone, and soft tissue. However, attention needs to be drawn to the high uptake of 11C-choline in some benign tumors and tumour-like lesions, as this will be of significance in clinical practice.
書誌情報 European Journal of Nuclear Medicine and Molecular Imaging

巻 31, 号 8, p. 1064-1072, 発行日 2004-08
ISSN
収録物識別子タイプ ISSN
収録物識別子 1619-7070
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:27:01.001403
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3