ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Dead regions and electric thickness in the CdTe(Cl) radiation detector

https://repo.qst.go.jp/records/43379
https://repo.qst.go.jp/records/43379
e91927ed-ca54-455e-be15-f79891f24698
Item type 学術雑誌論文 / Journal Article(1)
公開日 2004-05-05
タイトル
タイトル Dead regions and electric thickness in the CdTe(Cl) radiation detector
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Hirasawa, Masahiko

× Hirasawa, Masahiko

WEKO 431498

Hirasawa, Masahiko

Search repository
平澤 雅彦

× 平澤 雅彦

WEKO 431499

en 平澤 雅彦

Search repository
抄録
内容記述タイプ Abstract
内容記述 There is some possibility that many granular regions which have a Cl density approximately one order of magnitude higher than their surrounding region are distributed and have an extremely lower resistivity in high resistivity CdTe(Cl). When high resistivity CdTe(Cl) is used as a radiation detector, these granular regions behave almost like a metal and become dead regions. Measurements by the photon counting method showed that the CdTe(Cl) detector volume ratio includes approximately 15 % dead regions. Assuming that the dead regions are distributed as many granular conductor particles in the CdTe(Cl) detector, calculations showed that the practical electric thickness of the CdTe(Cl) detector is reduced to approximately 45 % of the real thickness. The characteristic of the response function of the CdTe(Cl) detector calculated using this electric thickness give good agreement with that given by the measured spectrum curve. This good agreement strongly supported the followings that approximately 15 % of the total volume is distributed as conductor particles, becoming dead regions and reducing the electric thickness to approximately 45 % in the CdTe(Cl) detector.
書誌情報 Radiation Detectors and Their Uses : Proceedings of the Workshop on Radiation Detectors and Their Uses(KEK Proceedings)

巻 15, p. 106-121, 発行日 2001-09
出版者
出版者 KEK
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:28:01.302646
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3