ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

EVALUATION OF THE EFFECTIVE DETECTION AREA OF RADIATION DETECTORS

https://repo.qst.go.jp/records/43330
https://repo.qst.go.jp/records/43330
48832443-ccbd-405f-a41b-4c62dfae803a
Item type 学術雑誌論文 / Journal Article(1)
公開日 2004-01-13
タイトル
タイトル EVALUATION OF THE EFFECTIVE DETECTION AREA OF RADIATION DETECTORS
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Ichitsubo, Hirokazu

× Ichitsubo, Hirokazu

WEKO 431023

Ichitsubo, Hirokazu

Search repository
Tokonami, Shinji

× Tokonami, Shinji

WEKO 431024

Tokonami, Shinji

Search repository
Miyamoto, Katsuhiro

× Miyamoto, Katsuhiro

WEKO 431025

Miyamoto, Katsuhiro

Search repository
Yamada, Yuji

× Yamada, Yuji

WEKO 431026

Yamada, Yuji

Search repository
一坪 宏和

× 一坪 宏和

WEKO 431027

en 一坪 宏和

Search repository
床次 眞司

× 床次 眞司

WEKO 431028

en 床次 眞司

Search repository
宮本 勝宏

× 宮本 勝宏

WEKO 431029

en 宮本 勝宏

Search repository
山田 裕司

× 山田 裕司

WEKO 431030

en 山田 裕司

Search repository
抄録
内容記述タイプ Abstract
内容記述 Radiation detectors (of the circular type) are utilized for the detection of radioactive particles deposited, e.g., (i) on each cascade impactor stage, in the measurement of radioactive aerosol particle size distribution and (ii) on air filters for the measurement of concentrations of radioactive aerosols (e.g. radon progeny) in the environment. The counting efficiency of the detector is related to both the geometric size of the detector, and the deposited area of radioactive aerosol particles. Although the detector size, for example, represents a constant factor unless the detector is exchanged, the area of deposition on the impactor stage or a filter is not of constant dimensions. When a cascade type impactor is used, the area of deposited aerosol particles is different for each impactor stage. In this report, we discuss the effects of both the geometric size of the detector, and the size of the area of deposition, on geometric counting efficiency. We also discuss the effective detection area of a radiation detector. The geometric counting efficiency decreases distinctly with increasing distance between the detector and the sample containing the deposited particles, when the area of deposited aerosol particles is equal in size to the detector. This result means that the effective diameter of the detector can be estimated by measuring the distinctive counting efficiency curve. We found that the actual working detection area (effective detection area) of radiation detectors available on the market could be calibrated by measuring the curve. If accurate measurement of size distribution is required using a particular kind of cascade impactor, detected radiation levels at each impactor stage should be corrected, including the parameters relating to the influence of the effective detection area of the detector, and for the actual area of deposition for the sample on each impactor stage.
書誌情報 High Levels of Natural Radiation and Radon Areas : Radiation Dose and Health Effects : Proceedings of the 5th International Conference on High Levels of Natural Radiation and Radon Areas, held in Munich,Germany on September 4 to 7, 2000 vol.II :Poster Presentation(BfS Schriften 24-2002)

p. 39-42, 発行日 2002-07
出版者
出版者 Bunddesamt fur Strahlenschutz
ISBN
識別子タイプ ISBN
関連識別子 3-8970-1808
戻る
0
views
See details
Views