ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Detection of lung cancer with positron coincidence gamma camera using fluorodeoxyglucose in comparison with dedicated PET

https://repo.qst.go.jp/records/43277
https://repo.qst.go.jp/records/43277
83f29377-7bd5-4778-b360-83dd41ad4044
Item type 学術雑誌論文 / Journal Article(1)
公開日 2003-11-21
タイトル
タイトル Detection of lung cancer with positron coincidence gamma camera using fluorodeoxyglucose in comparison with dedicated PET
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Zhang, Hong

× Zhang, Hong

WEKO 430495

Zhang, Hong

Search repository
Mei, Tian

× Mei, Tian

WEKO 430496

Mei, Tian

Search repository
Oriuchi, Noboru

× Oriuchi, Noboru

WEKO 430497

Oriuchi, Noboru

Search repository
Higuchi, Tetsuya

× Higuchi, Tetsuya

WEKO 430498

Higuchi, Tetsuya

Search repository
Tanada, Shuji

× Tanada, Shuji

WEKO 430499

Tanada, Shuji

Search repository
Endou, Keigo

× Endou, Keigo

WEKO 430500

Endou, Keigo

Search repository
張 宏

× 張 宏

WEKO 430501

en 張 宏

Search repository
棚田 修二

× 棚田 修二

WEKO 430502

en 棚田 修二

Search repository
遠藤 啓吾

× 遠藤 啓吾

WEKO 430503

en 遠藤 啓吾

Search repository
抄録
内容記述タイプ Abstract
内容記述 Objective: Dual-head gamma cameras with sodium iodide(NaI) detectors operated in coincidence mode provide a new approach for imaging with positron-labeled tracers. The purpose of this study was to evaluaate the feasibility of FDG imaging with positron coincidence detection gamma camera(PCD) in detecting lung tumor in comparison with FDG imaging with the dedicated positron emission tomography(PET). Methods and maaterial: Twenty-six lesions of 13patients with suspected lung cancer were studied with both FDG PET and FDG PCD on the same day. Pulmonary lesions were analyzed visually and semi-quantitatively using the ratio of target-to-background counts(T/B ratio). Results and conclusions: FDG PCD and FDG PET could detect visually 21 lesions(80.8percent) and 23 lesions(88.0percent), respectively. The mean T/B ratio and standard deviation(S.D.) of FDG PCD was 4.6+/-3.9, significantly lower than that of FDG PET(11.4+/-6.6,P<0.001). When pulmonary lesions were no more than 2.0 cm in diameter,the sensitivity of FDG PCD was 37.5percent, significantly inferior to that of FDG PEt(62.5percent,P<0.001). There was no statistically with uniform attenuation correction was clinically available in detecting lun cancer. However, the sensitivity for small lesions less than 2.0 cm was limited. The application of measured attenuation correction and scaatter correction may to be needed to improve the detectalbility of FDG PCD, especially for detecting small lung cancer.
書誌情報 European Journal of Radiology

巻 47, p. 199-205, 発行日 2003
ISSN
収録物識別子タイプ ISSN
収録物識別子 0720-048X
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:29:13.292344
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3