  1. 原著論文

Cytogenetical dose estimation for 3 severely exposed patients in the JCO criticality accident in Tokai-mura.

https://repo.qst.go.jp/records/43183
https://repo.qst.go.jp/records/43183
edfaafc6-5958-4d2b-a9c2-4402d2921167
Item type 学術雑誌論文 / Journal Article(1)
公開日 2003-10-20
タイトル
タイトル Cytogenetical dose estimation for 3 severely exposed patients in the JCO criticality accident in Tokai-mura.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Hayata, Isamu

× Hayata, Isamu

WEKO 429628

Hayata, Isamu

Search repository
Kanda, Reiko

× Kanda, Reiko

WEKO 429629

Kanda, Reiko

Search repository
Minamihisamatsu, Masako

× Minamihisamatsu, Masako

WEKO 429630

Minamihisamatsu, Masako

Search repository
Furukawa, Akira

× Furukawa, Akira

WEKO 429631

Furukawa, Akira

Search repository
Sasaki, Masao

× Sasaki, Masao

WEKO 429632

Sasaki, Masao

Search repository
早田 勇

× 早田 勇

WEKO 429633

en 早田 勇

Search repository
神田 玲子

× 神田 玲子

WEKO 429634

en 神田 玲子

Search repository
南久松 眞子

× 南久松 眞子

WEKO 429635

en 南久松 眞子

Search repository
古川 章

× 古川 章

WEKO 429636

en 古川 章

Search repository
佐々木 正夫

× 佐々木 正夫

WEKO 429637

en 佐々木 正夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 A dose estimation by chromosome analysis was performed on the 3 severely exposed patients in the Tokai-mura criticality accident. Drastically reduced lymphocyte counts suggested that the whole-body dose of radiation which they had been exposed to was unprecedentedly high. Because the number of lymphocytes in the white blood cells in two patients was very low, we could not culture and harvest cells by the conventional method. To collect the number of lymphocytes necessary for chromosome preparation, we processed blood samples by a modified method, called the high-yield chromosome preparation method. With this technique, we could culture and harvest cells, and then make air-dried chromosome slides. We applied a new dose-estimation method involving an artificially induced prematurely condensed ring chromosome, the PCC-ring method, to estimate an unusually high dose with a short time. The estimated doses by the PCC-ring method were in fairly good accordance with those by the conventional dicentric and ring chromosome (Dic+R) method. The biologically estimated dose was comparable with that estimated by a physical method. As far as we know, the estimated dose of the most severely exposed patient in the present study is the highest recorded among that chromosome analyses have been able to estimate in humans.
書誌情報 Journal of Radiation Research

巻 42, 号 Suppl., p. S149-S155, 発行日 2001-09
ISSN
収録物識別子タイプ ISSN
収録物識別子 0449-3060
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:30:18.258138
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3