Estimating Uncertainties of the Geometrical Range of particle Radiotherapy during Respiration

https://repo.qst.go.jp/records/43069
https://repo.qst.go.jp/records/43069
296e9e49-afe0-494c-bedc-20adcc150cc9
Item type 学術雑誌論文 / Journal Article(1)
公開日 2003-04-15
タイトル
タイトル Estimating Uncertainties of the Geometrical Range of particle Radiotherapy during Respiration
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Minohara, Shinichi

× Minohara, Shinichi

WEKO 428559

Minohara, Shinichi

Search repository
Endo, Masahiro

× Endo, Masahiro

WEKO 428560

Endo, Masahiro

Search repository
Kanai, Tatsuaki

× Kanai, Tatsuaki

WEKO 428561

Kanai, Tatsuaki

Search repository
Katou, Hirotoshi

× Katou, Hirotoshi

WEKO 428562

Katou, Hirotoshi

Search repository
Tsujii, Hirohiko

× Tsujii, Hirohiko

WEKO 428563

Tsujii, Hirohiko

Search repository
蓑原 伸一

× 蓑原 伸一

WEKO 428564

en 蓑原 伸一

Search repository
遠藤 真広

× 遠藤 真広

WEKO 428565

en 遠藤 真広

Search repository
金井 達明

× 金井 達明

WEKO 428566

en 金井 達明

Search repository
加藤 博敏

× 加藤 博敏

WEKO 428567

en 加藤 博敏

Search repository
辻井 博彦

× 辻井 博彦

WEKO 428568

en 辻井 博彦

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose: To propose a method for estimating uncertainties of the range calculation in particle radiotherapy
associated with patient respiration.
Methods and Materials: A set of sequential CT images at every 0.2 s was reconstructed from continuous X-ray
projection data accumulated by dynamic helical scanning. At the same time that CT data was acquired, the
respiratory signal of the patient and the X-ray on/off signal on CT scanner were recorded. Each CT image was
timed according to the phase of respiration waveform. Conversion of the CT number to the water equivalent path
length (WEL) was performed with our treatment planning system that included a conversion table. As an
illustration, the CT images of a patient with liver cancer at the right upper lobe were analyzed. The geometric
size of the liver and WELs from body surface to isocenter were measured in each CT image.
Results: Variations of WEL from body surface to isocenter at the anterior-posterior and posterior-anterior
direction were 6.2 mm and 18.9 mm, respectively. Liver size changed by 35.2 mm. However, these variations were
shown to be considerably reduced by gated irradiation.
Conclusion: A method using sequential CT images with respiration waveform was proposed. It appeared to be
useful in evaluating the uncertainties of the range calculation associated with patient breathing.
書誌情報 International Journal of Radiation Oncology Biology Physics

巻 56, 号 1, p. 121-125, 発行日 2003-05
ISSN
収録物識別子タイプ ISSN
収録物識別子 0360-3016
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:31:38.314528
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3