Dynamic analysis of chromosome aberrations in three victims of the Tokai-mura criticality accident.

https://repo.qst.go.jp/records/43057
https://repo.qst.go.jp/records/43057
6c680b37-7647-4a1f-a619-6feda39d12b1
Item type 学術雑誌論文 / Journal Article(1)
公開日 2003-02-21
タイトル
タイトル Dynamic analysis of chromosome aberrations in three victims of the Tokai-mura criticality accident.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kanda, Reiko

× Kanda, Reiko

WEKO 428476

Kanda, Reiko

Search repository
Minamihisamatsu, Masako

× Minamihisamatsu, Masako

WEKO 428477

Minamihisamatsu, Masako

Search repository
Hayata, Isamu

× Hayata, Isamu

WEKO 428478

Hayata, Isamu

Search repository
神田 玲子

× 神田 玲子

WEKO 428479

en 神田 玲子

Search repository
南久松 眞子

× 南久松 眞子

WEKO 428480

en 南久松 眞子

Search repository
早田 勇

× 早田 勇

WEKO 428481

en 早田 勇

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose: To investigate the dynamics of chromosome aberrations in the blood cells of three workers severely exposed to neutrons and gamma rays in a criticality accident that occurred in Tokai-mura, Japan, in 1999.
Materials and methods: The change with time of the frequency of chromosome aberrations in the three patients was examined using a new analysis to score drug-induced prematurely condensed ring chromosomes (PCC-R) and a conventional metaphase analysis.
Results: The frequencies and cellular distributions of PCC-R, dicentrics and rings did not change significantly among the samples obtained at 9-48h after the accident while the first depletion of lymphocytes occurred. The distributions of these aberrations in the cells of two patients showed a slight overdispersion compared with a Poisson distribution reflecting neutron and non-uniform exposures. The dose-response curve of rings paralleled that of dicentrics, but not PCC-R. The half-lives of PCC-R (8.5 months) and of rings (8.7 months) were shorter than that of dicentrics (13.5 months).
Conclusions: In the three patients of the Tokai-mura accident, lymphocytes in the circulating and extravascular pools had reached equilibrium at 9h, and highly damaged lymphocytes did not selectively move away from the circulatory system during the first rapid depletion of lymphocytes after exposure. Data on the in vivo half-life of PCC-R as well as dicentrics and rings obtained in the present study may be useful for retrospective dosimetry.
書誌情報 International Journal of Radiation Biology

巻 78, p. 857-862, 発行日 2002
ISSN
収録物識別子タイプ ISSN
収録物識別子 0955-3002
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:31:47.012445
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3