WEKO3
アイテム
Dynamic analysis of chromosome aberrations in three victims of the Tokai-mura criticality accident.
https://repo.qst.go.jp/records/43057
https://repo.qst.go.jp/records/430576c680b37-7647-4a1f-a619-6feda39d12b1
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2003-02-21 | |||||
タイトル | ||||||
タイトル | Dynamic analysis of chromosome aberrations in three victims of the Tokai-mura criticality accident. | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Kanda, Reiko
× Kanda, Reiko× Minamihisamatsu, Masako× Hayata, Isamu× 神田 玲子× 南久松 眞子× 早田 勇 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Purpose: To investigate the dynamics of chromosome aberrations in the blood cells of three workers severely exposed to neutrons and gamma rays in a criticality accident that occurred in Tokai-mura, Japan, in 1999. Materials and methods: The change with time of the frequency of chromosome aberrations in the three patients was examined using a new analysis to score drug-induced prematurely condensed ring chromosomes (PCC-R) and a conventional metaphase analysis. Results: The frequencies and cellular distributions of PCC-R, dicentrics and rings did not change significantly among the samples obtained at 9-48h after the accident while the first depletion of lymphocytes occurred. The distributions of these aberrations in the cells of two patients showed a slight overdispersion compared with a Poisson distribution reflecting neutron and non-uniform exposures. The dose-response curve of rings paralleled that of dicentrics, but not PCC-R. The half-lives of PCC-R (8.5 months) and of rings (8.7 months) were shorter than that of dicentrics (13.5 months). Conclusions: In the three patients of the Tokai-mura accident, lymphocytes in the circulating and extravascular pools had reached equilibrium at 9h, and highly damaged lymphocytes did not selectively move away from the circulatory system during the first rapid depletion of lymphocytes after exposure. Data on the in vivo half-life of PCC-R as well as dicentrics and rings obtained in the present study may be useful for retrospective dosimetry. |
|||||
書誌情報 |
International Journal of Radiation Biology 巻 78, p. 857-862, 発行日 2002 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0955-3002 |