ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Comparison of parametric FBP and OS-EM reconstruction algorithm images for PET dynamic study

https://repo.qst.go.jp/records/42982
https://repo.qst.go.jp/records/42982
32c349cc-0e38-4b3a-9361-1d4ce75baa9a
Item type 学術雑誌論文 / Journal Article(1)
公開日 2002-06-24
タイトル
タイトル Comparison of parametric FBP and OS-EM reconstruction algorithm images for PET dynamic study
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Oda, Keiichi

× Oda, Keiichi

WEKO 427688

Oda, Keiichi

Search repository
Toyama, Hinako

× Toyama, Hinako

WEKO 427689

Toyama, Hinako

Search repository
Uemura, Koji

× Uemura, Koji

WEKO 427690

Uemura, Koji

Search repository
Ikoma, Youko

× Ikoma, Youko

WEKO 427691

Ikoma, Youko

Search repository
Kimura, Yuichi

× Kimura, Yuichi

WEKO 427692

Kimura, Yuichi

Search repository
Senda, Michio

× Senda, Michio

WEKO 427693

Senda, Michio

Search repository
織田 圭一

× 織田 圭一

WEKO 427694

en 織田 圭一

Search repository
外山 比南子

× 外山 比南子

WEKO 427695

en 外山 比南子

Search repository
上村 幸司

× 上村 幸司

WEKO 427696

en 上村 幸司

Search repository
生駒 洋子

× 生駒 洋子

WEKO 427697

en 生駒 洋子

Search repository
木村 裕一

× 木村 裕一

WEKO 427698

en 木村 裕一

Search repository
抄録
内容記述タイプ Abstract
内容記述 An Ordered subsets expectation maximization(OS-EM) algorithm is used for image reconstruction to suppress image noise and to make non-negative value images. We have applied OS-EM to a digital brain phantom and to human brain 18F-FDG PET kinetic studies to generate parametric images. A 45 min dynamic scan was performed starting injection of FDG with a 2D PET scanner. The images were reconstructed with OS-EM(6 iterations,16 subsets)and with filtered backprijection(FBP),and K1 ,K2 and K3 images were created by the Marquardt non-linear least squares method based on the 3-parameter kinetic model.Although the OS-EM activity images correlated fairly well with those obtained by FBP,the pixel correlations were poor for the K2 and K3 parametric images,but the plots were scattered along the line of identity and the mean values for K1,K2 and K3 obtained by OS-EM were almost equal to those by FBP.The kinetic fitting error for OS-EM was no smaller than that for FBP.The results suggest that OS-EM is not necessarily superior to FBP for creating parametric images.
書誌情報 Annals of Nuclear Medicine

巻 15, 号 5, p. 417-423, 発行日 2001
ISSN
収録物識別子タイプ ISSN
収録物識別子 0914-7187
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:32:41.267757
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3