New in-vivo calibration phantoms and their performance

https://repo.qst.go.jp/records/42924
https://repo.qst.go.jp/records/42924
f5ddf500-69ba-4b6f-900c-d55559d353aa
Item type 学術雑誌論文 / Journal Article(1)
公開日 2002-06-11
タイトル
タイトル New in-vivo calibration phantoms and their performance
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Ishikawa, Tetsuo

× Ishikawa, Tetsuo

WEKO 427155

Ishikawa, Tetsuo

Search repository
Uchiyama, Masafumi

× Uchiyama, Masafumi

WEKO 427156

Uchiyama, Masafumi

Search repository
Hoshi, Masaharu

× Hoshi, Masaharu

WEKO 427157

Hoshi, Masaharu

Search repository
Takada, Jun

× Takada, Jun

WEKO 427158

Takada, Jun

Search repository
Endo, Satoru

× Endo, Satoru

WEKO 427159

Endo, Satoru

Search repository
Sugiura, Nobuyuki

× Sugiura, Nobuyuki

WEKO 427160

Sugiura, Nobuyuki

Search repository
Kosako, Toshisou

× Kosako, Toshisou

WEKO 427161

Kosako, Toshisou

Search repository
Shimizu, Isamu

× Shimizu, Isamu

WEKO 427162

Shimizu, Isamu

Search repository
石川 徹夫

× 石川 徹夫

WEKO 427163

en 石川 徹夫

Search repository
内山 正史

× 内山 正史

WEKO 427164

en 内山 正史

Search repository
星 正治

× 星 正治

WEKO 427165

en 星 正治

Search repository
高田 純

× 高田 純

WEKO 427166

en 高田 純

Search repository
遠藤 暁

× 遠藤 暁

WEKO 427167

en 遠藤 暁

Search repository
抄録
内容記述タイプ Abstract
内容記述 New in-vivo calibration phantoms (anthropometric phantoms) were developed to meet the needs for Japanese standard phantoms. Two important characteristics of these phantoms were that (1) they were designed using Japanese body size survey data, and (2) they were designed so that they can be adapted to various positions or geometries. The performance of these phantoms was tested with respect to body size, activity distribution along the axis, and counting efficiency. The actual dimensions of the anthropometric phantoms were compared with the survey data. Most items (31 of 47) indicated good agreement between the actual values and the survey data for the adult anthropometric phantom. The activity distribution for the anthropometric phantoms was compared with that for block phantoms that simulate a uniform activity distribution. The anthropometric phantoms have some gaps in their joints. The measurement results, however, indicated that these gaps did not significantly affect the overall accuracy of the measurements. Differences in counting efficiency between the block phantoms and the anthropometric phantoms for the same age were no more than 6%.
書誌情報 Health Physics

巻 82, p. 348-357, 発行日 2002-03
ISSN
収録物識別子タイプ ISSN
収録物識別子 0017-9078
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:33:20.964007
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3