内容記述 |
A preliminary thermal–hydraulic design of the water‑cooling system (WCS) for the Japanese water‑cooled ceramic breeder (WCCB) test blanket system (TBS) in ITER is presented. The WCS is designed to remove both surface heat flux from plasma irradiation and volumetric nuclear heating generated in the WCCB test blanket module (TBM) under reactor‑relevant conditions. Surface heat loads on the first wall, side walls, and baseplate were evaluated assuming a design heat flux of 0.3 MW m⁻², while nuclear heat loads were assessed using the MCNP6.1 code with the FENDL‑3.1d nuclear data library. As a result, the total heat load to the WCCB TBM was estimated to be 916 kW, comprising 320 kW of surface heating and 596 kW of nuclear heating. Based on these results, a detailed heat balance calculation of the WCS was conducted to determine mass flow rates, temperatures, and heat‑exchanger duties in the primary, intermediate, and purification loops. The required primary loop mass flow rate was determined to be 3.64 kg/s, ensuring sufficient heat removal within the specified temperature limits. Furthermore, pressure drop characteristics of the WCCB TBM were investigated using computational fluid dynamics (CFD) analyses. A full‑scale mock‑up experiment under pressurized water reactor–like conditions was performed to validate the CFD results. Good agreement between numerical and experimental results was obtained. Using a simplified submodule model, the total pressure drop of the WCCB TBM set was estimated to be 0.15 MPa, demonstrating the feasibility of the proposed WCS design. |