ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

Thermal-Hydraulic Design of Water Cooling System for Fusion Reactor Breeding Blanket

https://repo.qst.go.jp/records/2007733
https://repo.qst.go.jp/records/2007733
5ecdaf3d-4074-44d8-ac78-3da08eb5f031
アイテムタイプ 会議発表用資料 / Presentation(1)
公開日 2026-10-05
タイトル
タイトル Thermal-Hydraulic Design of Water Cooling System for Fusion Reactor Breeding Blanket
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference presentation
著者 Wenhai Guan

× Wenhai Guan

Wenhai Guan

Search repository
Tanno Kiyohito

× Tanno Kiyohito

Tanno Kiyohito

Search repository
Hirose Takanori

× Hirose Takanori

Hirose Takanori

Search repository
Kawamura Yoshinori

× Kawamura Yoshinori

Kawamura Yoshinori

Search repository
抄録
内容記述 A preliminary thermal–hydraulic design of the water‑cooling system (WCS) for the Japanese water‑cooled ceramic breeder (WCCB) test blanket system (TBS) in ITER is presented. The WCS is designed to remove both surface heat flux from plasma irradiation and volumetric nuclear heating generated in the WCCB test blanket module (TBM) under reactor‑relevant conditions. Surface heat loads on the first wall, side walls, and baseplate were evaluated assuming a design heat flux of 0.3 MW m⁻², while nuclear heat loads were assessed using the MCNP6.1 code with the FENDL‑3.1d nuclear data library. As a result, the total heat load to the WCCB TBM was estimated to be 916 kW, comprising 320 kW of surface heating and 596 kW of nuclear heating. Based on these results, a detailed heat balance calculation of the WCS was conducted to determine mass flow rates, temperatures, and heat‑exchanger duties in the primary, intermediate, and purification loops. The required primary loop mass flow rate was determined to be 3.64 kg/s, ensuring sufficient heat removal within the specified temperature limits. Furthermore, pressure drop characteristics of the WCCB TBM were investigated using computational fluid dynamics (CFD) analyses. A full‑scale mock‑up experiment under pressurized water reactor–like conditions was performed to validate the CFD results. Good agreement between numerical and experimental results was obtained. Using a simplified submodule model, the total pressure drop of the WCCB TBM set was estimated to be 0.15 MPa, demonstrating the feasibility of the proposed WCS design.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述 The 15th International Topical Meeting on Nuclear Reactor Thermal-Hydraulics, Operation, and Safety
発表年月日
日付 2026-10-01
戻る
0
views
See details
Views

Versions

Ver.1 2026-10-14 00:07:27.346608
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3