ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Fabrication of Tin vacancy centers in nanodiamonds

https://repo.qst.go.jp/records/2007205
https://repo.qst.go.jp/records/2007205
c0006f9d-5215-4a32-b0df-199b758f40b5
アイテムタイプ 会議発表用資料 / Presentation(1)
公開日 2025-03-02
タイトル
タイトル Fabrication of Tin vacancy centers in nanodiamonds
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6670
資源タイプ conference poster
著者 Hideaki Takashima

× Hideaki Takashima

Hideaki Takashima

Search repository
Konosuke Shimazaki

× Konosuke Shimazaki

Konosuke Shimazaki

Search repository
Abe Hiroshi

× Abe Hiroshi

Abe Hiroshi

Search repository
Ohshima Takeshi

× Ohshima Takeshi

Ohshima Takeshi

Search repository
Shigeki Takeuchi

× Shigeki Takeuchi

Shigeki Takeuchi

Search repository
抄録
内容記述 Nanodiamonds with color centers have recently become a focus of photonic quantum information technologies. Among the various vacancies in diamonds, Tin vacancy (SnV) centers have promising properties[3], such as high brightness, high emission efficiency (60%) from a zero-phonon line (ZPL) at about 620 nm, lifetime-limited linewidths, and a long coherence time of the electronic spin. A reported method for fabricating nanodiamonds, including SnV centers, is the synthesis by microwave plasma chemical vapor deposition[4]. In this method, inorganic compounds were used to introduce a layer of oxides and chlorides that serve Sn ions. However, this method would be difficult to precisely control both the size of the nanodiamonds and the number of defect centers. Here, we report an alternative approach for creating SnV centers in nanodiamonds using ion implantation. We use type-Ib diamond monocrystalline suspension (MSY 0.05, purchased from Microdiamant). Small amounts of the suspension are spin-coated several times on substrates. Sn ions are implanted into the samples with an energy of 800 KeV and ion fluence of 1014 ions/cm2. We then anneal the implanted samples in a high vacuum for about 20 hours at 1200oC. After annealing, the samples are heated at about 500 degrees to remove the sp2 carbon layer on the surface. Finally, the nanodiamonds are transferred to silica substrates. We use a confocal microscope system for the optical measurement. A continuous-wave laser (λ=520 nm) is used to excite the SnV centers in the nanodiamonds. The laser's excitation power is about 10 mW. The laser beam is focused on the nanodiamonds with an objective lens with a numerical aperture of 0.95. The samples are scanned at a step size of 200 nm using a three-axis piezo actuator. The fluorescence is collected with the same objective lens and measured by a single-photon counting module and a spectrometer.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述 Single Photon Workshop 2024
発表年月日
日付 2024-11-19
関連サイト
識別子タイプ URI
関連識別子 https://fitwise.eventsair.com/2024singlephotonworkshop/
戻る
0
views
See details
Views

Versions

Ver.1 2026-08-10 03:54:19.704028
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3