ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. プロシーディングス

A 64Cu-labeled peptide-based PET radiotracers for imaging PD-L1 expression in preclinical tumor models

https://repo.qst.go.jp/records/2004760
https://repo.qst.go.jp/records/2004760
74cf01f1-8027-40df-a79b-5d62df0e3933
アイテムタイプ 会議発表論文 / Conference Paper(1)
公開日 2023-11-02
タイトル
タイトル A 64Cu-labeled peptide-based PET radiotracers for imaging PD-L1 expression in preclinical tumor models
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_5794
資源タイプ conference paper
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Siqi Zhang

× Siqi Zhang

Siqi Zhang

Search repository
Kuan Hu

× Kuan Hu

Kuan Hu

Search repository
Lulu Zhang

× Lulu Zhang

Lulu Zhang

Search repository
Yanrong Wang

× Yanrong Wang

Yanrong Wang

Search repository
Xingkai Wang

× Xingkai Wang

Xingkai Wang

Search repository
Jieting Shen

× Jieting Shen

Jieting Shen

Search repository
Feng Wang

× Feng Wang

Feng Wang

Search repository
Zhang Ming-Rong

× Zhang Ming-Rong

Zhang Ming-Rong

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose/Background: The breakthrough in tumor therapy is the discovery of immune checkpoint proteins, which advances the development of immune checkpoint blockade therapy. Programmed cell death receptor 1 (PD-1) is a particularly interesting immune checkpoint in human cancers. The interaction between PD-1 and its ligand PD-L1 inactivates the antitumor response of T lymphocytes, thus suppressing the antitumor immune response. Currently, chromogenic immunohistochemistry (IHC) is the commonly used approach to identify appropriate patients who are most likely to respond to immune checkpoint therapy. However, due to the heterogeneous expression of PD-L1 in tumors, biopsy-based assays cannot precisely predict the tumor response to this therapy. Molecular imaging technology, such as positron emission tomography (PET), enables real-time visualization of the whole body in a non-invasive way and thus can outperform the conventional IHC method. Compared with antibodies, peptides have faster blood and healthy organ clearance and are more easily chemically modified. Therefore, we reported the synthesis of a peptide-based radiotracer, [64Cu]HKP2201, and investigate the utility for monitoring PD-L1 expression in preclinical models. Methods: Encouraged by the promising ICB activity of a previous reported PD-L1 targeted peptide CLP002 in animals, we assumed that it is a potential targeting vehicle for PET tracers. We generated the precursor peptide HKP2201 by conjugating of DOTA to CLP002 via a miniPEG spacer. The quality control for [64Cu]HKP2201 was conducted. Immunofluorescence and immunohistochemistry assay was performed to examine the PD-L1 expression in mouse melanoma cell line B16F10, mouse colon cancer cell line MC38 and their allografts. In vitro assays were conducted to examine the specificity and pharmacological properties of [64Cu]HKP2201. PET imaging and ex vivo biodistribution were assayed to investigate the in vivo performance of B16F10 and MC38 allografts bearing mice. Results: Synthesis of [64Cu]HKP2201 achieved high radiochemical yield and purity. Positive signals of PD-L1 expression were observed in B16F10 and MC38 cells and their tumor allografts. [64Cu]HKP2201 demonstrated a concentration-dependent cell affinity and a comparable half-maximal effect concentration (EC50) with [64Cu]WL12. Competitive binding revealed effective blockade by both WL12 (Ki, 41.64 nM) and PD-L1 antibody (Ki, 10.70 nM), suggesting a possible overlap of the binding groove between those peptides and PD-L1 antibodies. [64Cu]HKP2201 PET imaging studies showed a temporary high accumulation of radiotracer in tumor tissues. High radioactivity quickly appeared in the kidneys, indicating that the tracers were mainly excreted out of the body through the kidney-urinal bladder pathway. Furthermore, the ex vivo biodistribution results demonstrated that the tumor-to-organ ratios were all increased during the observation period, suggesting good tumor retention of [64Cu]HKP2201. Conclusion: We developed a novel linear peptide-based radiotracers, [64Cu]HKP2201, and demonstrated that the radiotracer were capable of imaging PD-L1 expression levels in mouse tumor models. To summarize, our study further expands the repertoire of the PD-L1 targeting PET imaging toolbox and provides potential radiotracer for accompanying diagnosis in ICB therapy.
書誌情報 SNMMI Annual Meeting Abstracts

巻 64, 発行日 2023-08
出版者
出版者 Society of Nuclear Medicine
ISSN
収録物識別子タイプ ISSN
収録物識別子 2159-662X
戻る
0
views
See details
Views

Versions

Ver.1 2026-08-07 04:05:33.854014
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3