ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Design and performance of a compact 3-GeV injector for the low-emittance storage ring in NanoTerasu

https://repo.qst.go.jp/records/2003326
https://repo.qst.go.jp/records/2003326
4cbe5f88-ef6d-445d-abbc-5751dd38bb79
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2026-05-25
タイトル
タイトル Design and performance of a compact 3-GeV injector for the low-emittance storage ring in NanoTerasu
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Kan Koichi

× Kan Koichi

Kan Koichi

Search repository
Asaka Takao

× Asaka Takao

Asaka Takao

Search repository
Ueshima Kouta

× Ueshima Kouta

Ueshima Kouta

Search repository
Obara Shuhei

× Obara Shuhei

Obara Shuhei

Search repository
Hosaka Yuji

× Hosaka Yuji

Hosaka Yuji

Search repository
Nishimori Nobuyuki

× Nishimori Nobuyuki

Nishimori Nobuyuki

Search repository
抄録
内容記述タイプ Abstract
内容記述 A 3-GeV linear accelerator was constructed as a full-energy injector, enabling high-efficiency and high-stability injection into NanoTerasu, a storage-ring light source with a multi-bend achromat lattice. The linear accelerator consists of a 40-MeV pre-injector and a C-band accelerator with a total length of 110 m. We developed a beam-based phase tuning method for RF cavities in the pre-injector. After this tuning, Twiss parameters and normalized emittance of less than 10 mm·mrad measured at the pre-injector exit are consistent with a beam tracking simulation. The 3-GeV linear accelerator has greatly contributed to stable top-up operation, since operation began in 2024. The energy stability of the injected beam from the linear accelerator was achieved as 0.04% (rms) during 11 days of X-ray user experiment with top-up mode. The stored beam current in the storage ring is maintained at 200 mA by top-up operation. The variation of the stored beam current is kept within 0.04% (rms) by the stable injected beam.
書誌情報 Nuclear Inst. and Methods in Physics Research, A

巻 1090, p. 171670-171670, 発行日 2026-05
出版者
出版者 Elsevier BV
DOI
識別子タイプ DOI
関連識別子 10.1016/j.nima.2026.171670
戻る
0
views
See details
Views

Versions

Ver.1 2026-05-29 00:19:27.621732
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3