| 著者 |
Nakamura Shoji
Shibahara Yuji
Shizuma Toshiyuki
Kimura Atsushi
Endo Shunsuke
Rovira Gerad
|
| 抄録 |
|
|
内容記述タイプ |
Abstract |
|
内容記述 |
In view of the requirement for accurate cross-section data of the stable Pb isotopes in order to discuss the neutron moderation effect and neutron economy in the design of accelerator-driven systems, the authors previously derived the thermal-neutron capture cross-section of Pb-204 by using thermal ionization mass spectrometry to be 0.537±0.030 barn. The uncertainty in the Pb-205/Pb-204 isotope ratio determined by mass spectrometry was 4.3%, bringing the total uncertainty to 5.6%. This study demonstrated that using a new silica-gel emitter used in mass spectrometry improved isotope ratio precision to 1%. This enabled the reaction rate to be determined with 1% accuracy, which exceeds the accuracy of conventional activation analysis. Owing to improved accuracy in mass spectrometry, the uncertainty has been reduced and the value of isotope ratio has changed slightly. Accordingly, the authors report a revised Pb-204 cross-section of 0.512±0.019 barn. |