  1. 原著論文

Revised Neutron Capture Cross Section of 204Pb by Accuracy Improvement of Thermal Ionization Mass Spectrometry

https://repo.qst.go.jp/records/2003263
https://repo.qst.go.jp/records/2003263
faf5186b-1c63-48f3-90c8-b2ea28540418
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2026-05-12
タイトル
タイトル Revised Neutron Capture Cross Section of 204Pb by Accuracy Improvement of Thermal Ionization Mass Spectrometry
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Nakamura Shoji

× Nakamura Shoji

Nakamura Shoji

Search repository
Shibahara Yuji

× Shibahara Yuji

Shibahara Yuji

Search repository
Shizuma Toshiyuki

× Shizuma Toshiyuki

Shizuma Toshiyuki

Search repository
Kimura Atsushi

× Kimura Atsushi

Kimura Atsushi

Search repository
Endo Shunsuke

× Endo Shunsuke

Endo Shunsuke

Search repository
Rovira Gerad

× Rovira Gerad

Rovira Gerad

Search repository
抄録
内容記述タイプ Abstract
内容記述 In view of the requirement for accurate cross-section data of the stable Pb isotopes in order to discuss the neutron moderation effect and neutron economy in the design of accelerator-driven systems, the authors previously derived the thermal-neutron capture cross-section of Pb-204 by using thermal ionization mass spectrometry to be 0.537±0.030 barn. The uncertainty in the Pb-205/Pb-204 isotope ratio determined by mass spectrometry was 4.3%, bringing the total uncertainty to 5.6%. This study demonstrated that using a new silica-gel emitter used in mass spectrometry improved isotope ratio precision to 1%. This enabled the reaction rate to be determined with 1% accuracy, which exceeds the accuracy of conventional activation analysis. Owing to improved accuracy in mass spectrometry, the uncertainty has been reduced and the value of isotope ratio has changed slightly. Accordingly, the authors report a revised Pb-204 cross-section of 0.512±0.019 barn.
書誌情報 Journal of Nuclear Science and Technology

発行日 2026-05
ISSN
収録物識別子タイプ ISSN
収録物識別子 0022-3131
DOI
識別子タイプ DOI
関連識別子 10.108
戻る
0
views
See details
Views

Versions

Ver.1 2026-05-15 00:37:00.670361
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3