ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Glow Discharge Boronization and Real-Time Boronization Using an Impurity Powder Dropper in LHD

https://repo.qst.go.jp/records/2003243
https://repo.qst.go.jp/records/2003243
5ef96ff9-572e-4911-837d-33ecd44527db
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2026-04-10
タイトル
タイトル Glow Discharge Boronization and Real-Time Boronization Using an Impurity Powder Dropper in LHD
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Suguru Masuzaki

× Suguru Masuzaki

Suguru Masuzaki

Search repository
Yoshimura Yasuo

× Yoshimura Yasuo

Yoshimura Yasuo

Search repository
抄録
内容記述タイプ Abstract
内容記述 In the Large Helical Device (LHD), boronization is utilized for wall conditioning, employing two distinct methods: glow discharge using diborane gas and the injection of boron powder into the plasma via an impurity powder dropper (IPD). Glow discharge boronization is conducted after maintenance when the vacuum vessel is exposed to air and just before the start of an experimental campaign. In contrast, real-time boronization using the IPD is performed during discharges. The distribution of boron on plasma-facing components was assessed through long-term material probes in the case of glow discharge and through numerical simulations for the IPD method. Results indicated non-uniform boron distributions in both cases. The impact of these boronization techniques on impurity levels and the lifetime of their effects were also examined. Both methods effectively reduced oxygen and iron in the plasma, with the iron impurities originating from the first wall. For glow discharge boronization, the reduction in oxygen levels persisted until the end of the experimental campaign, whereas the reduction in iron levels only lasted a few days. In the case of boron injection during long pulse discharges exceeding 200 s, the suppression of oxygen and iron was observed. The effect on iron quickly diminished within several seconds after the injection ended, whereas the effect on oxygen lasted more than 100 s. The difference in the lifetimes of the boronization effects is further discussed.
書誌情報 Nuclear Materials and Energy

巻 42, p. 101843, 発行日 2024-12
DOI
識別子タイプ DOI
関連識別子 10.1016/j.nme.2024.101843
戻る
0
views
See details
Views

Versions

Ver.1 2026-05-08 01:23:06.765653
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3