  1. 原著論文

Real-time Thomson Scattering Diagnostics and data processing for Plasma Control on LHD

https://repo.qst.go.jp/records/2003176
https://repo.qst.go.jp/records/2003176
70551619-1b8c-4742-88ac-1307ad2ce87a
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2026-04-17
タイトル
タイトル Real-time Thomson Scattering Diagnostics and data processing for Plasma Control on LHD
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 H. Funaba

× H. Funaba

H. Funaba

Search repository
I. Yamada

× I. Yamada

I. Yamada

Search repository
R. Yasuhara

× R. Yasuhara

R. Yasuhara

Search repository
Y. Morishita

× Y. Morishita

Y. Morishita

Search repository
N. Kenmochi

× N. Kenmochi

N. Kenmochi

Search repository
S. Murakami

× S. Murakami

S. Murakami

Search repository
H. Nakanishi

× H. Nakanishi

H. Nakanishi

Search repository
J.H. Lee

× J.H. Lee

J.H. Lee

Search repository
Akimitsu Moe

× Akimitsu Moe

Akimitsu Moe

Search repository
M. Yokoyama

× M. Yokoyama

M. Yokoyama

Search repository
M. Osakabe

× M. Osakabe

M. Osakabe

Search repository
抄録
内容記述タイプ Abstract
内容記述 Real-time measurement of the electron temperature and density is conducted in the Thomson scattering diagnostics on the Large Helical Device. The real-time data streaming is realized by the “RTRetrieve” system. It is operated with the repetition rate of 10 Hz and the delay time in the real-time Thomson scattering system is almost 50 ∼ 75 ms. The results of electron temperature and density by this real-time diagnostics are compared with the results by the usual processes which are made after the plasma discharge. The data are used as input for the plasma control system based on the data assimilation called ASTI (Assimilation System for Toroidal plasma Integrated simulation) in every 300 ms. The relation of the real-time Thomson scattering and the plasma control by ASTI is presented. Impact of the delay time on the ASTI based plasma control is analyzed in detail. This delay time is considered within the acceptable range.
書誌情報 Journal of Instrumentation (JINST)

巻 21, 号 4, p. C04042, 発行日 2026-04
出版者
出版者 IOP Publishing
DOI
識別子タイプ DOI
関連識別子 10.1088/1748-0221/21/04/C04042
戻る
0
views
See details
Views

Versions

Ver.1 2026-04-21 23:50:39.322823