ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Low-Cost Polyphenol-Polypyrrole Molecularly Imprinted Sensor for Point-of-Care Alzheimer's Detection.

https://repo.qst.go.jp/records/2003012
https://repo.qst.go.jp/records/2003012
9e02357a-b4ce-4097-9d5b-218a39f4005b
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2026-03-13
タイトル
タイトル Low-Cost Polyphenol-Polypyrrole Molecularly Imprinted Sensor for Point-of-Care Alzheimer's Detection.
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Ajith Mohan Arjun

× Ajith Mohan Arjun

Ajith Mohan Arjun

Search repository
Sudhaunsh Deshpande

× Sudhaunsh Deshpande

Sudhaunsh Deshpande

Search repository
Guoyi Liu

× Guoyi Liu

Guoyi Liu

Search repository
Daimei Miura

× Daimei Miura

Daimei Miura

Search repository
Krzysztof Pawlak

× Krzysztof Pawlak

Krzysztof Pawlak

Search repository
Tokuda Takahiko

× Tokuda Takahiko

Tokuda Takahiko

Search repository
Makoto Higuchi

× Makoto Higuchi

Makoto Higuchi

Search repository
Miyu Matsumoto

× Miyu Matsumoto

Miyu Matsumoto

Search repository
Tomoko Umemura

× Tomoko Umemura

Tomoko Umemura

Search repository
Kaori Tsukakoshi

× Kaori Tsukakoshi

Kaori Tsukakoshi

Search repository
Sanjiv Sharma

× Sanjiv Sharma

Sanjiv Sharma

Search repository
抄録
内容記述タイプ Abstract
内容記述 There is an urgent need for rapid, affordable diagnostics for Alzheimer's disease (AD), particularly those that can detect phosphorylated Tau 181 (p-tau181)─a key biomarker─directly in plasma. We present a scalable, label-free electrochemical biosensor fabricated on a printed circuit board platform, integrating a novel nanomolecularly imprinted polymer transducer based on a polyphenol red-polypyrrole composite. This platform enables sensitive detection of p-tau181 in undiluted plasma, serum, and clinical AD samples using a custom-designed potentiostat and machine learning-assisted classification. The sensor achieves a detection limit of 498 fg mL, a sensitivity of 8.99 μA/pg mL, and an area under the ROC curve (AUC) of 0.84 in clinical samples, comparable to the single molecule array (SIMOA) assay (AUC = 0.91), but at a fraction of the cost. This integrated platform, validated in real patient samples, demonstrates significant advancement toward accessible, point-of-care diagnostics for early AD detection.
書誌情報 ACS sensors

巻 10, 号 11, p. 8435-8446, 発行日 2025-11
ISSN
収録物識別子タイプ ISSN
収録物識別子 2379-3694
PubMed番号
識別子タイプ PMID
関連識別子 40814138
DOI
識別子タイプ DOI
関連識別子 10.1021/acssensors.5c01816
戻る
0
views
See details
Views

Versions

Ver.1 2026-04-06 05:23:53.402430
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3