ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

High-resolution TOF-DOI detectors with diode-based multiplexing for brain PET

https://repo.qst.go.jp/records/2002936
https://repo.qst.go.jp/records/2002936
9c4213fd-d946-4cdd-a319-a47b3d95957f
アイテムタイプ 会議発表用資料 / Presentation(1)
公開日 2026-03-03
タイトル
タイトル High-resolution TOF-DOI detectors with diode-based multiplexing for brain PET
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference presentation
著者 Hangyu Kang

× Hangyu Kang

Hangyu Kang

Search repository
Yoshida Eiji

× Yoshida Eiji

Yoshida Eiji

Search repository
Akamatsu Go

× Akamatsu Go

Akamatsu Go

Search repository
Yamaya Taiga

× Yamaya Taiga

Yamaya Taiga

Search repository
抄録
内容記述 For brain dedicated positron emission tomography (PET), time-of-flight (TOF) and depth-of-interaction (DOI) information is essential to improve PET image quality. In addition, signal multiplexing is required to reduce the number of data acquisition channels thereby reducing cost. Last year, we developed a TOF-PET detector with a diode-based row-column multiplexing (RC mux) circuit. However, the detector lacks DOI information, and the crystal pitch was large (3.2 mm). Here, we present the CLS (crosshair light sharing) detector with diode-based multiplexing for brain-dedicated TOF-DOI PET development. The CLS detector consists of fast-LGSO crystal 14×14 array (crystal pitch=1.6 mm, thickness=15 mm) and SiPM 8×8 array (S14160-3050HS, pixel pitch=3.2 mm) (Fig. 1(a)). Custom-made RC mux circuits were used to reduce the SiPM channels from 64 into 16 (8 x-position + 8 y-position) with diode and resistor materials, respectively (Fig. 1(b-c)). The multiplexed analog signals were digitized by using PETsys TOFPET2 ASIC modules with an energy window of 440-560 keV (Fig. 2(a)). The effects of the RC mux circuits on the CTR were evaluated (Fig. 2(b)), and the diode-based multiplexing did not degrade the CTR (378 ps), whereas the resistor-based multiplexing degraded the CTR by 34% (572 ps). In conclusion, the diode-based RC multiplexing is a cost-effective solution for the development of brain-dedicated TOF-DOI PET systems.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述 2026年第73回応用物理学会春季学術講演会
発表年月日
日付 2026-03-17
戻る
0
views
See details
Views

Versions

Ver.1 2026-03-05 05:40:50.561378
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3