ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Validation of stochastic method on track density analysis for passive radon measurement

https://repo.qst.go.jp/records/2002598
https://repo.qst.go.jp/records/2002598
2e437636-b0de-48fe-b1b1-47c40e85b9af
アイテムタイプ 会議発表用資料 / Presentation(1)
公開日 2026-01-08
タイトル
タイトル Validation of stochastic method on track density analysis for passive radon measurement
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6670
資源タイプ conference poster
著者 Hu Jun

× Hu Jun

Hu Jun

Search repository
Chutima Kranrod

× Chutima Kranrod

Chutima Kranrod

Search repository
Shinji Tokonami

× Shinji Tokonami

Shinji Tokonami

Search repository
抄録
内容記述 Passive radon monitors with CR-39s are commonly used in major epidemiological studies. However, the conventional CR-39 track density analysis method makes it difficult to estimate the concentration accurately due to the heterogeneity of tracks on CR-39s and the small track reading area. Track heterogeneity in CR-39 detectors arises from exposure-related and detector-related factors. To improve the accuracy of track density analysis in passive radon monitors, this study implemented a new stochastic approach utilizing Latin Hypercube Sampling (LHS) to compare the performance to the conventional method.Consequently, the root mean square deviation of 0.37 of mean track density using the stochastic method is lower than the conventional method of 0.39. The coefficient of determination of the stochastic method is significantly higher than that of the conventional method in the linear correlation of estimated track density and accumulated exposure. The stochastic method utilizing the LHS for track density analysis decreased the total counting area of CR-39 and performed congruently and effectively as the large counting area using the conventional strategy. These findings suggest the stochastic approach is a promising method for improving track density determination in passive radon measurements with CR-39 detectors.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述 第26回「環境放射能」研究会
発表年月日
日付 2025-03-12
戻る
0
views
See details
Views

Versions

Ver.1 2026-01-19 06:20:01.777003
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3