Improvement of the quench detection system for the PF coils of JT-60SA

https://repo.qst.go.jp/records/2002437
https://repo.qst.go.jp/records/2002437
75819c02-0e9f-49f3-a3f5-dff588ec825a
アイテムタイプ 会議発表用資料 / Presentation(1)
公開日 2025-10-07
タイトル
タイトル Improvement of the quench detection system for the PF coils of JT-60SA
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6670
資源タイプ conference poster
著者 Sonoda Shogo

× Sonoda Shogo

Sonoda Shogo

Search repository
Murakami Haruyuki

× Murakami Haruyuki

Murakami Haruyuki

Search repository
Usui Katsutomi

× Usui Katsutomi

Usui Katsutomi

Search repository
Hatakeyama Shoichi

× Hatakeyama Shoichi

Hatakeyama Shoichi

Search repository
Hamada Kazuya

× Hamada Kazuya

Hamada Kazuya

Search repository
Davis Sam

× Davis Sam

Davis Sam

Search repository
Wanner Manfred

× Wanner Manfred

Wanner Manfred

Search repository
Tomarchio Valerio

× Tomarchio Valerio

Tomarchio Valerio

Search repository
Zani Louis

× Zani Louis

Zani Louis

Search repository
Phillips Guy

× Phillips Guy

Phillips Guy

Search repository
Novello Luca

× Novello Luca

Novello Luca

Search repository
抄録
内容記述 The JT-60SA Poloidal Field (PF) coils comprise four central solenoid modules (CS) and six Equilibrium Field (EF1-6) coils. Their quench detection (QD) system uses pickup coils integrated in the coils to cancel inductive voltages during current transients and to detect any resistive voltage from a quench. A low pass filter, which consists of a resistor and a capacitor, is reducing the noise before the signal is fed to the differential amplifier of the QD. During the individual energization test of the PF coils in August 2023, spike-shaped noise was observed by the QD voltage when current transients were applied to PF coil. This spike must be reduced to avoid false detection of quench.Following a circuit analysis of EF2 coil it was found that the spike noise was caused by a small difference of the time constant of the RC filter circuit and of the pickup coil. The reduction of spike noise was experimentally confirmed by adjusting the time constants by a variable capacitor or resistor in the RC filter. Now the PF quench detectors are being modified to allow adjustment of the RC filter ready for the next tokamak operation.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述 17th European Conference on Applied Superconductivity
発表年月日
日付 2025-09-23
戻る
0
views
See details
Views

Versions

Ver.1 2026-01-19 00:58:38.922218