WEKO3
アイテム
BL13U of NanoTerasu: a beamline for soft and tender X-ray absorption spectroscopy with versatile photon polarization
https://repo.qst.go.jp/records/2001965
https://repo.qst.go.jp/records/20019650d2378c4-65bf-4a8a-ae36-fb668ba6e808
| アイテムタイプ | 会議発表論文 / Conference Paper(1) | |||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 公開日 | 2025-06-06 | |||||||||||||||||||||||||||||||||||
| タイトル | ||||||||||||||||||||||||||||||||||||
| タイトル | BL13U of NanoTerasu: a beamline for soft and tender X-ray absorption spectroscopy with versatile photon polarization | |||||||||||||||||||||||||||||||||||
| 言語 | en | |||||||||||||||||||||||||||||||||||
| 言語 | ||||||||||||||||||||||||||||||||||||
| 言語 | eng | |||||||||||||||||||||||||||||||||||
| 資源タイプ | ||||||||||||||||||||||||||||||||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||||||||||||||||||||||||||||||||
| 資源タイプ | conference paper | |||||||||||||||||||||||||||||||||||
| アクセス権 | ||||||||||||||||||||||||||||||||||||
| アクセス権 | metadata only access | |||||||||||||||||||||||||||||||||||
| アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||||||||||||||||||||||||||||||||
| 著者 |
Ohtsubo Yoshiyuki
× Ohtsubo Yoshiyuki
× Kitamura Miho
× Ueno Tetsuro
× Iwasawa Hideaki
× Yamamoto Kohei
× Miyawaki Jun
× Inaba Kento
× Agui Akane
× Inami Nobuhito
× Nakatani Takeshi
× Imazono Takashi
× Takeuchi Tomoyuki
× Fujii Kentaro
× Kimura Hiroaki
× Horiba Koji
|
|||||||||||||||||||||||||||||||||||
| 抄録 | ||||||||||||||||||||||||||||||||||||
| 内容記述タイプ | Abstract | |||||||||||||||||||||||||||||||||||
| 内容記述 | A synchrotron radiation beamline BL13U is under commissioning at NanoTerasu, the new 3 GeV high-brilliance synchrotron radiation facility at Tohoku, Japan. BL13U is dedicated for wide-energy-range X-ray absorption spectroscopy, in the soft to tender X-ray energy region (180-3000 eV) with versatile polarization control for x-ray magnetic circular/linear dichroism (XMCD/XMLD) measurements. The beamline optics are designed for balancing high photon flux and energy resolution. BL13U has achieved an energy resolution E/ΔE above 10000 at 400 eV, as well as sharp X-ray absorption spectra both in the soft X-ray and tender X-ray region from Boron K (∼190 eV) to Ruthenium L2 (∼2970 eV) edges. | |||||||||||||||||||||||||||||||||||
| 書誌情報 |
Journal of Physics: Conference Series 発行日 2025-06 |
|||||||||||||||||||||||||||||||||||
| DOI | ||||||||||||||||||||||||||||||||||||
| 識別子タイプ | DOI | |||||||||||||||||||||||||||||||||||
| 関連識別子 | 10.1088/1742-6596/3010/1/012079 | |||||||||||||||||||||||||||||||||||